For three GPUs:
• If intrusion switch is installed, the server supports up to two GPU adapters in PCIe slot 2 and slot 3.
• PCIe slot priority to install the GPU: PCIe slot 1, PCIe slot 3, PCIe slot 2.
• High-performance fan must be selected.
• Internal drive assembly and rear drive cage are not supported.
• PCIe SSD adapter is not supported.
• It can only be supported when servers are configured as 4 x 3.5" SAS/SATA, 8 x 2.5" SAS/SATA (6 x 2.5"
SAS/SATA + 2 x HDD vacant), 6 x 2.5" SAS/SATA + 4 x 2.5" AnyBay (6 x 2.5" SAS/SATA + 4 x HDD
vacant) or 10 x 2.5" AnyBay (6 x 2.5" 4 x HDD vacant).
– For 8 x 2.5" SAS/SATA (6 x 2.5" SAS/SATA + 2 x HDD vacant), if HDDs are installed in slots 0-5, two 1 x
2.5" single filler should be installed on slots 6 and 7.
– For 6 x 2.5" SAS/SATA + 4 x 2.5" AnyBay (6 x 2.5" SAS/SATA + 4 x HDD vacant), if HDDs are installed
in slots 0-5, four 1 x 2.5" single filler should be installed on slots 6, 7, 8 and 9.
– For 10 x 2.5" AnyBay (6 x 2.5" 4 x HDD vacant), if HDDs are installed in slots 0-5, four 1 x 2.5"
single filler should be installed on slots 6, 7, 8 and 9.
The following table lists the technical rules between NVIDIA Tesla T4 GPU adapters and processor TDP for
different configurations.
Supported configuration
for drives in front
backplane
NVIDIA Tesla T4 GPU
adapters
Processor TDP
Supported ambient
temperature
• 4 x 3.5-inch SAS/SATA
• 8 x 2.5-inch SAS/SATA
• 6 x 2.5-inch SAS/SATA
+ 4 x 2.5-inch AnyBay
• 10 x 2.5-inch AnyBay
2
120 watts
up to 35°C
• 4 x 3.5-inch SAS/SATA
• 8 x 2.5-inch SAS/SATA
• 6 x 2.5-inch SAS/SATA
+ 4 x 2.5-inch AnyBay
• 10 x 2.5-inch AnyBay
2
120/155/180/200 watts
up to 30°C
• 4 x 3.5-inch SAS/SATA
• 6 x 2.5-inch SAS/SATA+
2 vacant drive bays
• 6 x 2.5-inch 4
vacant drive bays
3
120 watts
up to 30°C
For NVIDIA Quadro P620, the rules of installing one to three GPUs are the same. See the following:
• If intrusion switch is installed, the server supports up to two GPU adapters in PCIe slot 2 and slot 3.
• PCIe slot priority to install the GPU: PCIe slot 1, PCIe slot 3, PCIe slot 2.
• High-performance fan must be selected.
• Internal drive assembly and rear drive cage are not supported.
• PCIe SSD adapter is not supported.
86
ThinkSystem SR635 Maintenance Manual
Summary of Contents for ThinkSystem SR635
Page 1: ...ThinkSystem SR635 Maintenance Manual Machine Types 7Y98 and 7Y99 ...
Page 5: ...Index 231 Copyright Lenovo 2019 2021 iii ...
Page 6: ...iv ThinkSystem SR635 Maintenance Manual ...
Page 10: ...viii ThinkSystem SR635 Maintenance Manual ...
Page 12: ...Figure 2 QR code 2 ThinkSystem SR635 Maintenance Manual ...
Page 22: ...12 ThinkSystem SR635 Maintenance Manual ...
Page 88: ...78 ThinkSystem SR635 Maintenance Manual ...
Page 133: ...Figure 102 Riser 1 assembly LP FHFL removal Chapter 3 Hardware replacement procedures 123 ...
Page 136: ...Figure 105 Riser 1 assembly LP FHFL installation 126 ThinkSystem SR635 Maintenance Manual ...
Page 214: ...204 ThinkSystem SR635 Maintenance Manual ...
Page 232: ...222 ThinkSystem SR635 Maintenance Manual ...
Page 240: ...230 ThinkSystem SR635 Maintenance Manual ...
Page 245: ......
Page 246: ......