Chapter 5: Initializing the NE10032
83
Out-of-Band Management Interface Configuration
Complete the following steps to configure an out-of-band management IP address
and a default gateway:
1.
Log onto the switch using the serial console port or management port on the
NE10032 front panel.
2.
Enter the management interface configuration mode:
3.
Configure an IP address and subnet mask:
4.
Configure the out-of-band default gateway:
In-Band Management Interface Configuration
Complete the following steps to configure an in-band management IP address over
an SVI interface and an associated default gateway:
1.
Log onto the switch using the serial console port or management port on the
NE10032 front panel.
2.
Enter the SVI interface configuration mode:
3.
Configure the in-band management IP address:
4.
Configure the in-band default gateway:
NE10032>
enable
NE10032#
configure [terminal]
NE10032(config)#
interface mgmt 0
NE10032(config-if)#
NE10032(config-if)#
ip address 10.254.87.6/24
NE10032(config-if)#
exit
NE10032(config)#
NE10032(config)#
vrf context management
NE10032(config-vrf)#
ip route 0.0.0.0/0 205.21.17.1
NE10032(config-vrf)#
exit
NE10032(config)#
NE10032>
enable
NE10032#
configure [terminal]
NE10032(config)#
NE10032(config)#
interface vlan 1
NE10032(config-if)#
ip address 10.254.87.6/24
NE10032(config-if)#
exit
NE10032(config)#
NE10032(config)#
ip route 0.0.0.0/0 205.21.17.1
Summary of Contents for ThinkSystem NE10032
Page 6: ...6 Lenovo NE10032 Installation Guide ...
Page 16: ...16 NE10032 Installation Guide ...
Page 58: ...58 NE10032 Installation Guide ...
Page 76: ...76 NE10032 Installation Guide ...
Page 92: ...92 NE10032 Installation Guide ...
Page 108: ...108 NE10032 Installation Guide ...
Page 114: ...114 NE10032 Installation Guide ...