10. Reinstall the front bezel. See “Removing and reinstalling the front bezel” on page 32.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to “Completing the parts replacement” on page 64.
Replacing the front fan assembly
Attention:
Do not open your server or attempt any repair before reading and understanding the
Safety Information
and the
Warranty and Support Information
on the documentation DVD that came with your product, and “Guidelines” on page
27. To obtain a copy of the publications, go to:
http://support.lenovo.com
Depending on the model type, your server might have a front fan assembly installed. This section provides
instructions on how to replace the front fan assembly.
To replace the front fan assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 31.
3. Remove the front bezel. See “Removing and reinstalling the front bezel” on page 32.
4. Disconnect the front fan assembly cable from the power fan connector on the system board. See
“Locating parts on the system board” on page 24.
Note:
If your server has a secondary hard disk drive installed, remove the secondary hard disk drive
to get easier access to the power fan connector on the system board. See “Installing or replacing the
secondary hard disk drive” on page 44.
Chapter 5
.
Replacing FRUs
53
Summary of Contents for ThinkSERVER TS130
Page 1: ...ThinkServer TS130 Hardware Maintenance Manual Machine Types 1098 1100 1105 and 1106 ...
Page 16: ...12 ThinkServer TS130 Hardware Maintenance Manual ...
Page 24: ...20 ThinkServer TS130 Hardware Maintenance Manual ...
Page 30: ...26 ThinkServer TS130 Hardware Maintenance Manual ...
Page 84: ...80 ThinkServer TS130 Hardware Maintenance Manual ...
Page 108: ...104 ThinkServer TS130 Hardware Maintenance Manual ...
Page 126: ...122 ThinkServer TS130 Hardware Maintenance Manual ...
Page 127: ......