11. Press the hard disk drive cage downward until it snaps into position. Make sure that the hard disk
drive cage is secured in the chassis.
Figure 24. Installing the secondary hard disk drive
12. Connect one end of the signal cable to the hard disk drive and the other end to an available SATA
connector on the system board. See “Locating parts on the system board” on page 24. Then, locate an
available five-wire power connector and connect it to the hard disk drive.
Figure 25. Connecting a SATA hard disk drive
Installing, removing, or replacing hardware devices
This section provides instructions on how to install, remove, or replace hardware devices for your server.
You can maintain your server by replacing the failing hardware devices. If you are replacing a hardware
device, perform the removal procedure and then perform the installation procedure for the hardware device
that you want to replace.
Chapter 5
.
Replacing FRUs
47