Removing the microprocessor 2 air baffle
When you work with some optional devices, you must first remove the
microprocessor 2 air baffle to access certain components. The following illustration
shows how to remove the microprocessor 2 air baffle.
1
Hole
2
Pin
3
Microprocessor 2 air baffle
4
Tab
5
PCI riser-card assembly 2
To remove the microprocessor 2 air baffle, complete the following steps:
1. Read the safety information that begins on page 3.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables (see “Turning off the server” on page 53).
3. Remove the cover.
4. Remove PCI riser-card assembly 2 (see “Removing a PCI riser-card assembly”
on page 167).
5. Grasp the top of the air baffle and lift the air baffle out of the server.
Attention:
For proper cooling and airflow, replace all air baffles before you
turn on the server. Operating the server with any air baffle removed might
damage server components.
Chapter 6. Removing and installing FRUs
175
Summary of Contents for THINKSERVER 3729
Page 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Page 2: ......
Page 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 265: ......
Page 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...