6. Remove the air baffle over the DIMMs (see “Removing the DIMM air baffle” on
page 177).
Attention:
To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
7. Open the retaining clip
2
on each end of the DIMM connector and lift the
DIMM
1
from the connector.
8. If you are instructed to return the DIMM, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Installing a memory module
The following notes describe the types of dual inline memory modules (DIMMs) that
the server supports and other information that you must consider when installing
DIMMs:
Chapter 6. Removing and installing FRUs
187