To install a hot-swap drive, complete the following steps:
Step 1. Install the hot-swap drive.
Figure 21. 3.5-inch hot-swap drive installation
a. Ensure that the drive tray handle is in the open position. Slide the drive into the drive bay until it
snaps into position.
b. Close the drive tray handle to lock the drive in place.
Step 2. Bring the data drive online by using the procedure
in the
Step 3. Bring the data drive online with the procedure
.
Step 4. Check the drive status LED to verify that the drive is operating correctly.
• If the yellow drive status LED is lit continuously, that drive is faulty and must be replaced.
• If the green drive activity LED is flashing, the drive is being accessed.
After installing all hot-swap drives, if you have removed the security bezel, reinstall it.
Hot-swap power supply replacement
Follow these instructions to replace a power supply unit in the ThinkAgile HX1321, and HX3321 Series
appliance.
The ThinkAgile HX1321, and HX3321 Series appliances use two power supply units. Those power supplies
are redundant when using 208 - 230V input power, allowing one power supply to meet the needs of the
node. Losing one power supply may not impact node operation; however, replace a failed power supply as
soon as possible to restore redundancy.
Table 9. Power supply options
Feature
Display Description
ThinkAgile HX3321
AVWC
ThinkSystem 550W(230V/115V) Platinum Hot-Swap Power Supply
AVWD
ThinkSystem 750W(230/115V) Platinum Hot-Swap Power Supply
√
AVWE
ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply
√
AVWF
ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply
√
.
Hardware replacement procedures
49
Summary of Contents for ThinkAgile HX Series
Page 1: ...User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node Machine Types 7Y89 7Z04 ...
Page 4: ...ii User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 16: ...12 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 36: ...32 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 42: ...38 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 90: ...86 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 94: ...90 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 96: ...92 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 98: ...94 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 100: ...96 User Guide for ThinkAgile HX1321 Node ThinkAgile HX3321 Node ...
Page 103: ......
Page 104: ......