TS − 3 to 5 Ton R−410A Air Conditioners
ARI RATINGS
1
ARI Standard 210/240 Ratings
E
i
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
tsa048s4
4 TON
Down-Flow Indoor Coils + Furnace
Down−Flow Coils
+ Furnace
46,500
13.50
11.00
4085
CR33−60D−F
4
G61MPV−60D−135
2
91M02
46,500
13.50
11.00
4085
CR33−60D−F
4
G71MPP−60D−135
2
91M02
46,500
13.50
11.00
4100
CR33−50/60C−F
4
G60DFV−60C−110
2
91M02
46,500
13.50
11.00
4140
CR33−50/60C−F
4
G71MPP−60C−110
2
91M02
46,500
13.50
11.00
4140
CR33−50/60C−F
4
G61MPV−60C−110
2
91M02
46,500
13.50
11.00
4145
CR33−50/60C−F
4
G71MPP−60C−090
2
91M02
46,500
13.50
11.00
4145
CR33−50/60C−F
4
G61MPV−60C−090
2
91M02
47,000
13.50
11.00
4100
CR33−50/60C−F
4
G60DFV−60C−090
2
91M02
47,000
13.50
11.50
4075
CR33−60D−F
4
G60DFV−60D−135
2
91M02
Horizontal Indoor Coils
Horizontal Coils
47,000
13.00
11.00
4260
3
CH33−44/48B−2F
2
91M02
47,000
13.00
11.00
4260
3
CH33−48C−2F
2
91M02
47,500
13.00
11.00
4320
3
CH33−43C−2F
2
91M02
47,500
13.00
11.00
4265
3
CH33−60D−2F
2
91M02
47,500
13.50
11.00
4265
3
CH23−68
2
91M02
48,000
13.50
11.00
4365
3
CH33−49C−2F
2
91M02
48,000
13.50
11.00
4265
3
CH33−50/60C−2F
2
91M02
48,000
13.50
11.00
4365
3
CH33−62D−2F
2
91M02
Horizontal Indoor Coils + Furnace
Horizontal Coils
+ Furnace
47,500
13.50
11.00
4320
CH33−43C−2F
4
G71MPP−60C−090
2
91M02
47,500
13.50
11.00
4320
CH33−43C−2F
4
G61MPV−60C−090
2
91M02
47,500
13.50
11.00
4320
CH33−43C−2F
4
G61MPV−60C−091
2
91M02
47,500
13.50
11.00
4320
CH33−43C−2F
4
G61MPV−60C−110
2
91M02
47,500
13.50
11.00
4320
CH33−43C−2F
4
G71MPP−60C−110
2
91M02
47,500
13.50
11.00
4320
CH33−43C−2F
4
G61MPV−60C−111
2
91M02
47,500
13.50
11.00
4180
CH33−48C−2F
4
G61MPV−60C−090
2
91M02
47,500
13.50
11.00
4180
CH33−48C−2F
4
G71MPP−60C−090
2
91M02
47,500
13.50
11.00
4180
CH33−48C−2F
4
G61MPV−60C−110
2
91M02
47,500
13.50
11.00
4180
CH33−48C−2F
4
G71MPP−60C−110
2
91M02
47,500
13.50
11.50
4135
CH33−48C−2F
4
G60UHV−60C−110
2
91M02
47,500
13.50
11.50
4140
CH33−48C−2F
4
G60UHV−60C−090
2
91M02
48,000
13.50
11.50
4175
CH33−43C−2F
4
G60UHV−60C−110
2
91M02
48,000
13.50
11.50
4185
CH33−50/60C−2F
4
G71MPP−60C−090
2
91M02
48,000
13.50
11.50
4185
CH33−50/60C−2F
4
G61MPV−60C−090
2
91M02
48,000
13.50
11.50
4185
CH33−50/60C−2F
4
G71MPP−60C−110
2
91M02
48,000
13.50
11.50
4185
CH33−50/60C−2F
4
G61MPV−60C−110
2
91M02
48,000
14.00
11.50
4175
CH33−43C−2F
4
G60UHV−60C−090
2
91M02
48,000
14.00
11.50
4040
CH33−60D−2F
4
G60UHV−60D−135
2
91M02
48,000
14.00
11.50
4040
CH23−68
4
G60UHV−60D−135
2
91M02
48,000
14.00
11.50
4095
CH33−60D−2F
4
G71MPP−60D−135
2
91M02
48,000
14.00
11.50
4095
CH33−60D−2F
4
G61MPV−60D−135
2
91M02
48,000
14.00
11.50
4095
CH23−68
4
G71MPP−60D−135
2
91M02
48,000
14.00
11.50
4095
CH23−68
4
G61MPV−60D−135
2
91M02
Horizontal Indoor Coils + Furnace
Continued on Next Page
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.