TS − 3 to 5 Ton R−410A Air Conditioners
/ Page 14
ARI RATINGS
1
ARI Standard 210/240 Ratings
E
i
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
tsa048s4
4 TON
Up-Flow Indoor Coils
Up−Flow Coils
47,000
13.00
11.00
4255
3
CX34−38A/B−6F
2
91M02
47,000
13.00
11.00
4255
3, 5
CX34−50/60C−6F
Factory TXV
47,500
13.00
11.00
4260
3
CX34−43B/C−6F
2
91M02
48,000
13.50
11.00
4265
3
CX34−60D−6F
Factory TXV
48,000
13.50
11.00
4270
3
CX34−49C−6F
Factory TXV
48,500
13.50
11.00
4270
3
CX34−62D−6F
Factory TXV
49,000
13.50
11.50
4270
3
CX34−62C−6F
Factory TXV
Up-Flow Indoor Coils + Furnace
Up−Flow Coils
+ Furnace
47,000
13.50
11.00
4155
CX34−50/60C−6F
4
G61MPV−60C−110
Factory TXV
47,000
13.50
11.00
4155
CX34−50/60C−6F
4
G71MPP−60C−110
Factory TXV
47,000
13.50
11.00
4165
CX34−50/60C−6F
4
G61MPV−60C−090
Factory TXV
47,000
13.50
11.00
4165
CX34−50/60C−6F
4
G71MPP−60C−090
Factory TXV
47,500
13.50
11.50
4115
CX34−50/60C−6F
4
G60UHV−60C−110
Factory TXV
47,500
13.50
11.50
4120
CX34−50/60C−6F
4
G60UHV−60C−090
Factory TXV
47,500
13.50
11.50
4145
CX34−43C−6F
4
G71MPP−60C−110
2
91M02
47,500
13.50
11.50
4145
CX34−43C−6F
4
G61MPV−60C−110
2
91M02
47,500
13.50
11.50
4155
CX34−43C−6F
4
G71MPP−60C−090
2
91M02
47,500
13.50
11.50
4155
CX34−43C−6F
4
G61MPV−60C−090
2
91M02
47,500
14.00
11.50
4105
CX34−43C−6F
4
G60UHV−60C−110
2
91M02
48,000
14.00
11.50
4110
CX34−43C−6F
4
G60UHV−60C−090
2
91M02
48,500
14.00
11.50
4080
CX34−60D−6F
4
G61MPV−60D−135
Factory TXV
48,500
14.00
11.50
4080
CX34−60D−6F
4
G71MPP−60D−135
Factory TXV
48,500
14.00
11.50
4110
CX34−49C−6F
4
G60UHV−60C−110
Factory TXV
48,500
14.00
11.50
4155
CX34−49C−6F
4
G61MPV−60C−110
Factory TXV
48,500
14.00
11.50
4155
CX34−49C−6F
4
G71MPP−60C−110
Factory TXV
48,500
14.00
11.50
4160
CX34−49C−6F
4
G61MPV−60C−090
Factory TXV
48,500
14.00
11.50
4160
CX34−49C−6F
4
G71MPP−60C−090
Factory TXV
48,500
14.00
12.00
4020
CX34−60D−6F
4
G60UHV−60D−135
Factory TXV
49,000
14.00
11.50
4120
CX34−49C−6F
4
G60UHV−60C−090
Factory TXV
49,000
14.00
11.50
4180
CX34−62C−6F
4
G61MPV−60C−090
Factory TXV
49,000
14.00
11.50
4180
CX34−62C−6F
4
G71MPP−60C−090
Factory TXV
49,000
14.00
12.00
4025
CX34−62D−6F
4
G60UHV−60D−135
Factory TXV
49,000
14.00
12.00
4085
CX34−62D−6F
4
G61MPV−60D−135
Factory TXV
49,000
14.00
12.00
4085
CX34−62D−6F
4
G71MPP−60D−135
Factory TXV
49,500
14.00
11.50
4135
CX34−62C−6F
4
G60UHV−60C−090
Factory TXV
49,500
14.00
11.50
4305
CX34−62C−6F
4
G61MPV−60C−110
Factory TXV
49,500
14.00
11.50
4305
CX34−62C−6F
4
G71MPP−60C−110
Factory TXV
49,500
14.00
12.00
4130
CX34−62C−6F
4
G60UHV−60C−110
Factory TXV
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.