TS − 3 to 5 Ton R−410A Air Conditioners 

/ Page 3

FEATURES

REFRIGERANT SYSTEM − CONTINUED

Copper Tube/Enhanced Fin Coil

Lennox designed and fabricated coil.
Ripple-edged aluminum fins.
Copper tube construction.
Lanced fins provide maximum exposure of fin surface to
air stream resulting in excellent heat transfer.
Fin collars grip tubing for maximum contact area.
Flared shoulder tubing connections/silver soldering
construction.
Coil is factory tested under high pressure to ensure
leakproof construction.
Entire coil is accessible for cleaning.
PVC coated steel wire coil guard furnished as standard.

High Pressure Switch Kit

Protects the system from high pressure conditions that
can be a result of fan failure or a blocked/dirty coil.
Manual reset.

OPTIONS

Expansion Valve Kits

Must be ordered extra and field installed on certain indoor
units. See ARI Ratings tables.
Chatleff−style fittings.

Loss of Charge Kit

Helps protect the compressor from damage due to low
refrigerant charge conditions.
SPST, normally−closed switch, automatic reset switch
mounted on suction line.

Refrigerant Line Kits

Refrigerant lines (suction & liquid) are shipped refrigeration
clean. Lines are cleaned, dried, pressurized and sealed at
factory.
Suction line fully insulated.
Lines are stubbed at both ends.
Not available for −060 models and must be field fabricated.

Compressor

Copeland Scroll

t

 Compressor

Compressor features high
efficiency with uniform suction
flow, constant discharge flow
and high volumetric efficiency
and quiet operation.
Compressor consists of two
involute spiral scrolls matched
together to generate a series of
crescent shaped gas pockets
between them.
During compression, one scroll
remains stationary while the
other scroll orbits around it.
Gas is drawn into the outer
pocket, the pocket is sealed as
the scroll rotates.
As the spiral movement
continues, gas pockets are pushed to the center of the
scrolls. Volume between the pockets is simultaneously
reduced.
When pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center of
the fixed scrolls.
During compression, several pockets are compressed
simultaneously resulting in a smooth continuous
compression cycle.
Continuous flank contact, maintained by centrifugal force,
minimizes gas leakage and maximizes efficiency.
Scroll compressor is tolerant to the effects of slugging and
contaminants. If this occurs, scrolls separate, allowing
liquid or contaminants to to be worked toward the center
and discharged.
Low gas pulses during compression reduces operational
sound levels.
Compressor motor is internally protected from excessive
current and temperature.
Compressor is installed in the unit on resilient rubber
mounts for vibration free operation.

Compressor Crankcase Heater

Protects against refrigerant migration that can occur
during low ambient operation.

OPTIONS

Compressor Low Ambient Cut−Off

Non-adjustable switch (low ambient cut-out) prevents
compressor operation when outdoor temperature is
below 35°F.

Compressor Sound Cover

A reinforced vinyl compressor cover containing a 1−1/2
inch thick batt of fiberglass insulation.
All open edges are sealed with a one−inch wide hook and
loop fastening tape.

Compressor Timed−Off Control

Kit prevents compressor short−cycling and allows time for
suction and discharge pressure to equalize.
Permits compressor start−up in an unloaded condition.
Automatic reset with 5 minute delay between compressor
shut−off and start−up.

C

D

Summary of Contents for TSA036S4

Page 1: ...or Design Sequence A 1st Generation B 2nd Generation Brand Family T T Classt Product Line Unit Type S Split System Air Conditioner Nominal Cooling Capacity Tons 036 3 Tons 042 3 5 Tons 048 4 Tons 060...

Page 2: ...on utility bills and help protect the environment Applications SEER up to 14 0 3 through 5 ton Three phase power supply Vertical air discharge allows concealment behind shrubs at grade level or out o...

Page 3: ...between them During compression one scroll remains stationary while the other scroll orbits around it Gas is drawn into the outer pocket the pocket is sealed as the scroll rotates As the spiral moveme...

Page 4: ...for outdoor units High density polyethylene structural material is lightweight sturdy sound absorbing and will withstand the rigors of the sun heat cold moisture oil and refrigerant Will not mildew or...

Page 5: ...cessories For Touchscreen Thermostat Locking cover clear C0MISC15AE1 1 Remote sensors for C0STAT02AE1L can be applied in the following combinations 1 C0SNZN01AE1 2 C0SNZN73AE1 2 C0SNZN01AE1 and 1 C0SN...

Page 6: ...mpressor Rated load amps 10 4 5 8 13 5 6 0 13 7 6 2 4 8 15 6 7 8 5 8 Power factor 85 84 83 81 90 92 88 90 91 90 Locked rotor amps 73 38 88 44 83 1 41 30 4 110 52 35 5 Outdoor Fan Motor Full load amps...

Page 7: ...ained between two units 48 in 1219 mm clearance required on top of unit See NOTES See NOTES See NOTES See NOTES CONTROL BOX OUTDOOR SOUND DATA 1 Unit Model No Octave Band Sound Power Levels dBA re 10...

Page 8: ...S LIQUID LINE CONNECTION TOP VIEW BASE SECTION 4 3 8 111 COMPRESSOR COIL DRAIN OUTLETS Around perimeter of base OPTIONAL UNIT STAND OFF KIT 4 Field Installed B C A OPTIONAL UNIT STAND OFF KIT 4 Field...

Page 9: ...6F C33 24A 2 CX34 18 24B 6F C33 24B 2 CX34 18 24C 6F C33 24C 2 CX34 19A 6F C33 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34...

Page 10: ...43B 6F 4 G60UHV 36B 090 2 37L51 35 600 14 00 12 00 2965 CX34 50 60C 6F 4 G60UHV 60C 110 2 37L51 36 400 14 00 11 60 3140 CX34 50 60C 6F 4 G61MPV 60C 091 2 37L51 36 400 14 00 11 60 3140 CX34 50 60C 6F 4...

Page 11: ...00 2965 4 CBX32MV 048 Multi Position 2 37L51 36 200 14 00 12 00 3015 3 CBX27UH 042 Up Flow Horizontal 2 37L51 TSA042S4 3 5 TON Up Flow Indoor Coils Up Flow Coils 40 000 13 00 10 80 3700 3 CX34 38A B...

Page 12: ...L72 41 000 14 00 11 50 3495 CR33 60D F 4 G71MPP 60D 135 2 39L72 41 000 14 00 11 50 3495 CR33 60D F 4 G61MPV 60D 135 2 39L72 41 000 14 00 11 50 3515 CR33 50 60C F 4 G60DFV 60C 110 2 39L72 41 000 14 00...

Page 13: ...11 50 3575 CH33 50 60C 2F 4 G71MPP 60C 110 2 39L72 41 500 13 50 11 50 3575 CH33 50 60C 2F 4 G61MPV 60C 110 2 39L72 41 500 13 50 11 50 3615 CH33 50 60C 2F 4 G71MPP 60C 090 2 39L72 41 500 13 50 11 50 3...

Page 14: ...G61MPV 60D 135 Factory TXV 48 500 14 00 11 50 4080 CX34 60D 6F 4 G71MPP 60D 135 Factory TXV 48 500 14 00 11 50 4110 CX34 49C 6F 4 G60UHV 60C 110 Factory TXV 48 500 14 00 11 50 4155 CX34 49C 6F 4 G61MP...

Page 15: ...320 CH33 43C 2F 4 G71MPP 60C 110 2 91M02 47 500 13 50 11 00 4320 CH33 43C 2F 4 G61MPV 60C 111 2 91M02 47 500 13 50 11 00 4180 CH33 48C 2F 4 G61MPV 60C 090 2 91M02 47 500 13 50 11 00 4180 CH33 48C 2F 4...

Page 16: ...M02 48 500 14 00 12 00 4045 CH33 62D 2F 4 G60UHV 60D 135 2 91M02 48 500 14 00 11 50 4100 CH33 62D 2F 4 G71MPP 60D 135 2 91M02 48 500 14 00 11 50 4100 CH33 62D 2F 4 G61MPV 60D 135 2 91M02 Air Handlers...

Page 17: ...C 6F 4 G71MPP 60C 110 Factory TXV 62 000 13 50 11 50 5420 CX34 62C 6F 4 G61MPV 60C 090 Factory TXV 62 000 13 50 11 50 5420 CX34 62C 6F 4 G71MPP 60C 090 Factory TXV 62 000 14 00 11 50 5250 CX34 62C 6F...

Page 18: ...2F 4 G71MPP 60D 135 2 91M02 60 500 13 50 11 00 5500 CH33 50 60C 2F 4 G60UHV 60C 090 2 91M02 60 500 13 50 11 50 5195 CH33 60D 2F 4 G60UHV 60D 135 2 91M02 61 000 14 00 11 50 5200 CH33 62D 2F 4 G60UHV 60...

Page 19: ...acturer s proprietary products and recommended installation Retain Reference Article when specifying products and installation by an industry reference standard If retained list standard s referenced...

Page 20: ...Control equipment shipped loose showing final location in assembly d Field wiring diagrams e Dimensions internal and external construction details installation clearances recommended method of install...

Page 21: ...lace until installation Specifier Note Include or remove following section as project dictates E Waste Management and Disposal Specifier Note ENVIRONMENT The disposal of packaging waste into landfill...

Page 22: ...ries 1 Hail Guards Four sided of louvered heavy gauge steel painted to match cabinet 2 Mounting Base of high density polyethylene structural material for permanent foundation of outdoor units 3 Unit S...

Page 23: ...in the USA 9 All units are to be factory run tested 10 Installer responsibilities a Set unit b Connect refrigerant lines c Make electrical connections Specifier Note Edit article below to suit project...

Page 24: ...st technical information www lennoxcommercial com Contact us at 1 800 9 LENNOX NOTE Due to Lennox ongoing committment to quality Specifications Ratings and Dimensions subject to change without notice...

Reviews: