TS − 3 to 5 Ton R−410A Air Conditioners
FEATURES
REFRIGERANT SYSTEM − CONTINUED
Copper Tube/Enhanced Fin Coil
Lennox designed and fabricated coil.
Ripple-edged aluminum fins.
Copper tube construction.
Lanced fins provide maximum exposure of fin surface to
air stream resulting in excellent heat transfer.
Fin collars grip tubing for maximum contact area.
Flared shoulder tubing connections/silver soldering
construction.
Coil is factory tested under high pressure to ensure
leakproof construction.
Entire coil is accessible for cleaning.
PVC coated steel wire coil guard furnished as standard.
High Pressure Switch Kit
Protects the system from high pressure conditions that
can be a result of fan failure or a blocked/dirty coil.
Manual reset.
OPTIONS
Expansion Valve Kits
Must be ordered extra and field installed on certain indoor
units. See ARI Ratings tables.
Chatleff−style fittings.
Loss of Charge Kit
Helps protect the compressor from damage due to low
refrigerant charge conditions.
SPST, normally−closed switch, automatic reset switch
mounted on suction line.
Refrigerant Line Kits
Refrigerant lines (suction & liquid) are shipped refrigeration
clean. Lines are cleaned, dried, pressurized and sealed at
factory.
Suction line fully insulated.
Lines are stubbed at both ends.
Not available for −060 models and must be field fabricated.
Compressor
Copeland Scroll
t
Compressor
Compressor features high
efficiency with uniform suction
flow, constant discharge flow
and high volumetric efficiency
and quiet operation.
Compressor consists of two
involute spiral scrolls matched
together to generate a series of
crescent shaped gas pockets
between them.
During compression, one scroll
remains stationary while the
other scroll orbits around it.
Gas is drawn into the outer
pocket, the pocket is sealed as
the scroll rotates.
As the spiral movement
continues, gas pockets are pushed to the center of the
scrolls. Volume between the pockets is simultaneously
reduced.
When pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center of
the fixed scrolls.
During compression, several pockets are compressed
simultaneously resulting in a smooth continuous
compression cycle.
Continuous flank contact, maintained by centrifugal force,
minimizes gas leakage and maximizes efficiency.
Scroll compressor is tolerant to the effects of slugging and
contaminants. If this occurs, scrolls separate, allowing
liquid or contaminants to to be worked toward the center
and discharged.
Low gas pulses during compression reduces operational
sound levels.
Compressor motor is internally protected from excessive
current and temperature.
Compressor is installed in the unit on resilient rubber
mounts for vibration free operation.
Compressor Crankcase Heater
Protects against refrigerant migration that can occur
during low ambient operation.
OPTIONS
Compressor Low Ambient Cut−Off
Non-adjustable switch (low ambient cut-out) prevents
compressor operation when outdoor temperature is
below 35°F.
Compressor Sound Cover
A reinforced vinyl compressor cover containing a 1−1/2
inch thick batt of fiberglass insulation.
All open edges are sealed with a one−inch wide hook and
loop fastening tape.
Compressor Timed−Off Control
Kit prevents compressor short−cycling and allows time for
suction and discharge pressure to equalize.
Permits compressor start−up in an unloaded condition.
Automatic reset with 5 minute delay between compressor
shut−off and start−up.
C
D