TS − 3 to 5 Ton R−410A Air Conditioners
/ Page 10
ARI RATINGS
1
ARI Standard 210/240 Ratings
E
i
Cooling Capacity
Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Device
Btuh
SEER
EER
Total Unit
Watts
Device
TSA036S4
3 TON
Up-Flow Indoor Coils
Up−Flow Coils
33,800
13.00
10.90
3100
3, 5
CX34−38B−6F
Factory TXV
34,600
13.00
11.00
3145
3
CX34−50/60C−6F
2
37L51
34,800
13.00
11.00
3165
3
CX34−43B−6F
2
37L51
Up-Flow Indoor Coils + Furnace
Up−Flow Coils
+ Furnace
34,400
13.50
11.50
2990
CX34−36C−6F
4
G61MPV−36C−090
Factory TXV
34,400
13.50
11.50
2990
CX34−36C−6F
4
G71MPP−36C−090
Factory TXV
34,800
14.00
11.60
3000
CX34−38B−6F
4
G61MPV−36B−070
Factory TXV
34,800
14.00
11.60
3000
CX34−38B−6F
4
G71MPP−36B−070
Factory TXV
35,000
13.50
11.60
3015
CX34−38A−6F
4
G60UHV−36A−070
Factory TXV
35,000
13.50
11.60
3015
CX34−38B−6F
4
G61MPV−36B−045
Factory TXV
35,200
14.00
11.60
3035
CX34−38B−6F
4
G60UHV−36B−090
Factory TXV
35,200
14.00
11.60
3035
CX34−43B−6F
4
G61MPV−36B−045
2
37L51
35,200
14.00
11.60
3035
CX34−43B−6F
4
G61MPV−36B−070
2
37L51
35,200
14.00
11.60
3035
CX34−43B−6F
4
G71MPP−36B−070
2
37L51
35,600
14.00
11.60
3070
CX34−43B−6F
4
G61MPV−36B−071
2
37L51
35,600
14.00
11.60
3070
CX34−50/60C−6F
4
G61MPV−60C−090
2
37L51
35,600
14.00
11.60
3070
CX34−50/60C−6F
4
G71MPP−60C−090
2
37L51
35,600
14.00
12.00
2965
CX34−43B−6F
4
G60UHV−36B−090
2
37L51
35,600
14.00
12.00
2965
CX34−50/60C−6F
4
G60UHV−60C−110
2
37L51
36,400
14.00
11.60
3140
CX34−50/60C−6F
4
G61MPV−60C−091
2
37L51
36,400
14.00
11.60
3140
CX34−50/60C−6F
4
G61MPV−60C−111
2
37L51
Down-Flow Indoor Coils
Down−Flow Coils
34,000
13.00
11.00
3090
3
CR33−48B−F
2
37L51
Down-Flow Indoor Coils + Furnace
Down−Flow Coils
+ Furnace
33,400
13.50
11.00
3035
CR33−48B−F
4
G61MPV−36B−070
2
37L51
33,400
13.50
11.00
3035
CR33−48B−F
4
G71MPP−36B−070
2
37L51
33,600
13.00
11.00
3055
CR33−48B−F
4
G61MPV−36B−045
2
37L51
33,800
14.00
11.60
2915
CR33−48B−F
4
G60DFV−36B−090
2
37L51
34,200
13.50
11.00
3110
CR33−48B−F
4
G61MPV−36B−071
2
37L51
34,800
13.50
11.50
3025
CR33−30/36C−F
4
G61MPV−36C−090
2
37L51
34,800
13.50
11.50
3025
CR33−30/36C−F
4
G71MPP−36C−090
2
37L51
Horizontal Indoor Coils
Horizontal Coils
34,600
13.00
11.00
3145
3
CH33−44/48B−2F
2
37L51
34,800
13.00
11.00
3165
3
CH33−48C−2F
2
37L51
36,200
13.50
11.00
3290
3
CH33−43B−2F
2
37L51
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95
_
F outdoor air temperature, 80
_
F db/67
_
F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.