background image

13

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

DIRECT VENT SYSTEM COMPONENTS 

The following "Security Secure Vent

TM 

" or "Simpson Dura-Vent" brand Direct-Vent components may be safely used with these appliances.

    Model #           SECURITY SECURE-VENT - Description

IMPORTANT NOTE: Seal the fi rst section of pipe to the stove collar using mill-pac black, high temperature sealant.

Note: Snorkel Caps: These are elongate vent termination caps, which incorporate the principles of natural draft into a horizontal installation. Two styles 
are common, 14” and 36” (Cap height). They enhance draft and relieve back-pressure by creating natural draft in the snorkel.

Table 8

     Model #       SIMPSON DURA-VENT Description

N/A 

N/A 

970 

Basic Horizontal Term. Kit (90 Deg. Black Elbow, 

Wall Thimble Cover, Horizontal Square Term. Cap) 

N/A 

N/A 

971 

Horizontal Term. Kit A (90 Deg. Black Elbow, Wall 

Thimble Cover, Horizontal Square Term. Cap, adj. 

24  black pipe, 11-14 5/8  adj. black pipe) 

SV4FK 

Vertical Flat Roof Term. Kit (w/flashing, storm collar, 

vertical Term. Cap) 

973 

Vertical Termination Kit (990B, 940, 984) 

SV4FAK 

Vertical  pitched Roof Kit, 1/12-7/12 (with adjustable 

roof flashing, storm collar, vertical termination cap) 

978 

Vertical Pitched Roof Kit, 0/12 6/1 2 (with 

adjustable flashing, storm collar, low profile term. 

Cap) 

SV4FBK 

Vertical  pitched Roof  Kit, 8/12-12/12 (with adjustable 

roof flashing, storm collar, vertical termination cap) 

N/A N/A 

SV4L6 

6  Pipe Length (Galvanized) 

908 

6  Pipe Length (Galvanized) 

SV4LB6 

6  Pipe Length (Black) 

908B 

6  Pipe Length (Black) 

N/A 

N/A 

907B 

9  Pipe Length ( Black) 

SV4L12 

12  Pipe Length (Galvanized) 

906 

12  Pipe Length (Galvanized) 

SV4LB12 

12  Pipe Length (Black) 

906B 

12  Pipe Length (Black) 

SV4L24 

24  Pipe Length (Galvanized) 

904 

24  Pipe Length (Galvanized) 

SV4LB24 

24  Pipe Length (Black) 

904B 

24  Pipe Length (Black) 

SV4L36 

36  Pipe Length (Galvanized) 

903 

36  Pipe Length (Galvanized) 

SV4LB36 

36  Pipe Length (Black) 

903B 

36  Pipe Length (Black) 

SV4L48 

48  Pipe Length (Galvanized) 

902 

48  Pipe Length (Galvanized) 

SV4LB48 

48  Pipe Length (Black) 

902B 

48  Pipe Length (Black) 

SV4LA 

6  Adj. Pipe Length, (Galvanized) 

908 

6  Adj. Pipe Length, (Galvanized) 

SV4LBA 

6  Adj. Pipe Length (Black) 

N/A 

N/A 

SV4LA12 

12  Adj. Pipe Length, (Galvanized) 

911 

11 -14 5/8  Adj. Pipe Length (Galvanized) 

SV4LBA12 

12  Adj. Pipe Length, (Black) 

911B 

11 -14 5/8  Adj. Pipe Length (Black) 

SV4E45 

45 Deg. Elbow, Swivel (Galvanized) 

945G 

45 Deg. Elbow, Swivel (Galvanized) 

SV4EB45 

45 Deg. Elbow, Swivel (Black) 

945BG 

45 Deg. Elbow, Swivel (Black) 

SV4E90 

90 Deg. Elbow, Swivel (Galvanized) 

990G 

90 Deg. Elbow, Swivel (Galvanized) 

SV4EB90 

90 Deg. Elbow, Swivel (Black) 

990BG 

90 Deg. Elbow, Swivel (Black) 

SV4E90 

90 Deg. Elbow (Galvanized) 

990 

90 Deg. Elbow (Galvanized) 

SV4EB90 

90 Deg. Elbow (Black). 

990B 

90 Deg. Elbow (Black) 

SV4CHC-1 

Horizontal Standard Term. Cap 

984 Horizontal 

Standard Term. Cap 

N/A 

N/A 

991 

Vertical High Wind Term. Cap 

SV4CGV 

Vertical Termination Cap 

N/A 

N/A 

SV4STC36 

Snorkel Termination Cap 36  

981 

Snorkel Termination Cap 36  

SV4STC14 

Snorkel Termination Cap 14  

982 

Snorkel Termination Cap 14  

SV4VS 

Vinyl Shield Protector 

950 

Vinyl Siding Standoff 

SV4SF 

Round Ceiling Support / Wall Thimble Cover 

940 

Round Ceiling Support / Wall Thimble Cover 

SV4CSB 

Cathedral Ceiling Support Box, decorative square 

941 

Cathedral Ceiling Support Box 

SV4PF 

Black Plate, Decorative, Square 

N/A 

N/A 

SV4SU 

Universal Support 

942 

Round Ceiling Support Box/Wall Thimble 

SV4FC 

Storm Collar 

953 

Storm Collar 

SV4RSM Wall 

Radiation 

Shield 

N/A  N/A 

SV4BF

 Firestop 

963 Firestop 

Spacer 

SV4F 

Flashing, Flat Roof (storm collar included) 

N/A 

N/A 

SV4FA 

Flashing, Adjustable roof 1/12-7/12 (storm collar 

included) 

943 Flashing 

0/12-6/12 

SV4FB 

Flashing, Adjustable 8/12-12/12 (storm collar included) 

943S Flashing 

7/12-12/12 

SV4BM 

Wall Band (Strap) 

988 

Wall Strap 

Summary of Contents for SEREFINA CI1500DVF series

Page 1: ...E OU LA MORT POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser d essencenid autrevapeursouliquidesinflammablesdans le voisinage de cet appareil ou de tout autre appareil POUR VOTRE SÉCURITÉ Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez Evacuez la piéce ...

Page 2: ...used Millivolt appliances are designed to oper ate on natural or propane gas A millivolt gas control valve with piezo ignition system provides safe efficient operation External electrical power is required to operate the optional blower if installed on these units Note Installation and repair should be per formed by a qualified service person The appliance should be inspected annually by a qualifi...

Page 3: ...e appliances and their individual shut off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1 2 psig 3 5 kPa These appliances must be isolated from the gas supply piping system by closing their individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or l...

Page 4: ...mm H 40 1016 mm 48 1 2 1232 mm Specifications CI1500DVF CI2500DVF Min Max BTU hr Input NG 17 500 28 000 25 500 38 500 Min Max BTU hr Input LP 20 500 27 000 26 500 34 500 DV Vent Size 4 inner 6 5 8 outer 4 inner 6 5 8 outer Room Fan CFM 150 150 Weight lb 206 290 Efficiencies CI1500DVF CI2500DVF EnerGuide P4 67 NG 65 LP 67 NG 64 LP Steady State Efficiency 85 NG 87 LP 83 NG 85 LP Note Due to Lennox o...

Page 5: ... alcove that allows for the minimum clearances to combustible surfaces Your local building inspector should review your plans prior to installation When installing this appliance provide adequate clearances for the purposes of servicing and proper operation As determined through the safety certification of this unit a minimum clearance to combustible materials must be maintained around specific ar...

Page 6: ...additionalvent location restrictions refer to Figure 5 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a guidelineanddonotsupersedelocalcodesin anyway Installventaccordingtolocalcodes these instructions the current National Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CGA B149 1 and B149 2 in Canada Side Elevation View Q...

Page 7: ... n i w t n e v e r p o t d e d n e m m o c e r m m 9 2 2 9 n o i t a s n e d n o c w o d n i w t i f f o s d e t a l i t n e v o t e c n a r a e l c l a c i t r e V D l a t n o z i r o h a n i h t i w l a n i m r e t e h t e v o b a d e t a c o l r e t n e c e h t m o r f m m 8 5 4 s e h c n i 8 1 f o e c n a t s i d l a n i m r e t e h t f o e n i l m m 8 5 4 8 1 m m 8 5 4 8 1 t i f f o s d e t a...

Page 8: ...et aside Step5 Page8 Removepackagedmaterials from inside firebox and set aside log set bag of embers and NG to LP conversion kit Step 6 Page 9 Remove cardboard packag ing material from beneath relief door and discard Step 7 Page 9 Install LP Conversion kit if necessary Install any optional accessories excluding firescreens Step 8 Page 9 Install lower access door Step 9 Page 9 Venting System Instal...

Page 9: ...control wiring system of the unit to a 120 volt power supply residential line voltage Thegasvalveissetinplaceandpre wiredatthe factory on both models see Figure 11 SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP ON OFF Switch Optional Thermostat Remote Control Receiver SWITCH Figure 10 Bl...

Page 10: ...see Figures 13 and 14 SupportBrackets Installventsupportbrack ets as specified in the vent manufacturers instructions and the National Gas Fuel Code USA NFPA 54 ANSI Z223 1 7 6 5 Support ofGasVents Gasventsshallbesupportedand spaced in accordance with their listings and the vent manufacturer instructions General Information These instructions should be used as a guideline and do not supersedelocal...

Page 11: ...ance for Natural Gas and 36 for Propane Gas before the first elbow The horizontal run may extend up to 20 feet 6 meters and include a vertical rise of up to 40 feet 12 meters see Figure 13 Horizontal termination must meet the criteria shown in Figures 4 and 5 Approved vent systems must terminate above and including the heavy line in Figure 13 Two 45 degree elbows may be substituted for each single...

Page 12: ...nversion Kit for 6 I D 1 insulation SV4CCK2 Factory Built Chimney Conversion Kit for 7 I D 1 insulation 8 I D 1 insulation 6 I D 2 insulation SV4CCK3 Factory Built Chimney Conversion Kit for 10 I D 1 insulation 7 I D 2 insulation 8 I D 2 insulation Model Brand SIMPSON DURA VENT Description 934 Masonry Chimney Conversion Kit 931 Factory Built Chimney Conversion Kit A for 6 I D 932 Factory Built Chi...

Page 13: ...Black 904B 24 Pipe Length Black SV4L36 36 Pipe Length Galvanized 903 36 Pipe Length Galvanized SV4LB36 36 Pipe Length Black 903B 36 Pipe Length Black SV4L48 48 Pipe Length Galvanized 902 48 Pipe Length Galvanized SV4LB48 48 Pipe Length Black 902B 48 Pipe Length Black SV4LA 6 Adj Pipe Length Galvanized 908 6 Adj Pipe Length Galvanized SV4LBA 6 Adj Pipe Length Black N A N A SV4LA12 12 Adj Pipe Lengt...

Page 14: ...inlet port fitting Figure 20 Ember Strip Rear Log Figure 21 Left Front Log Figure 22 2 Place the largest log onto the rear log stoppers see Figure 20 Ensure that the grooves on the bottom of the log aligns onto the corresponding places on the rear log stoppers Push the log back so that it is against the back of the rear log stoppers see Figure 21 3 Place the left front log onto the corre sponding ...

Page 15: ...ethefineembermaterial mineral wool into dime sized fluffy pieces b Distribute the pieces over the top of the front burner ports avoiding covering the slots see Figure 29 and filling the area in front of the forward logs Figure 26 Figure 27 Figure 29 VERIFY THAT THE GAS LINE HAS BEEN PURGED OF AIR SEE STEP 10 Figure 25 Left Top Twig Step 12 RE INSTALL FRONT GLASS ENCLOSURE PANEL Reverse instruction...

Page 16: ...d run initial system checkout before closing up the front of the unit Follow the pilot lighting instruc tions provided in the Homeowner s Care and Operation Instructions or pull out the instruction label located in a holder on rear shield of stove For piezo igniter location see Figure 30 Fasten the two latches located beneath the firebox floor to the glass frame vee flange Close both the latches s...

Page 17: ...15 9 mm CI2500DVF 1 2 12 7 mm 5 8 15 9 mm Initially always position the air shutter to the factorysettingasshowninFigure34 adjust mentrodislocatedinthelowercontrolarea This can be done by moving the adjustment rodupordownaccordingly Allowtheburner to operate for at least 15 minutes Observe the flame continuously If it appears weak or sooty as previously described adjust the air shutter to a more o...

Page 18: ...MBRE DE SERIE XXXXX XXXXX IIIIIIIIIIIIIIIIIIII XXXXXXXXXXXXXXXX P N 9 1452A MODEL NO CI1500DVF SERIES MANUFACTURED AT SANTA TERESA NM FOR USE WITH NATURAL GAS EQUIPE POUR GAZ NATUREL ALTITUDE MIN GAS SUPPLY PRESS WC PRESS MIN D ALIMENTATION CE MANIFOLD PRESSURE WC PRESSION CE TUBULURE CE MANUFACTURER S RECOMMENDED ORIFICE SIZE DIMENSION DE L INJECTEUR RECOMMANDE PAR MANUFACTURIER DMS MAX INPUT BTU...

Page 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE ...

Page 20: ...ts P N 775 147M REV D 11 2006 1110 West Taft Avenue Orange CA 92865 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information ...