Table 15. Model / Compressor Cross-Reference
ODU Model #
Compressor Model #
Blue - Red
Blue - Black
Red - Blue
MLA018S4S-1P
MLA024S4S-1P
ATF235D22UMT
0.75 Ω
MLA018S4M-1P
ATF235D22UMT
0.75 Ω
MLA030S4M-1P
ATF310D43UMT
0.65 Ω
MLA036S4M-1P
ATQ360D1UMU
0.37 Ω
29.2. IPM Check
Measure the resistance value of each winding by using the tester.
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Table 16. Normal Resistance Values
Digital Tester
Normal Resistance Value
Digital Tester
Normal Resistance Value
(+)Red
(-)Black
∞
(Several MΩ)
(+)Red
(-)Black
∞
(Several MΩ)
P
N
U
N
U
V
V
W
W
(+)Red
Figure 75. Testing