131
Error Code:
E3
Description:
Indoor fan speed error.
General Note:
When indoor fan speed runs too low (300RPM) for a certain time, the unit will stop and the LED will display the error.
Indoor fan speed error
Power off, then restart the unit 2 minutes
later. Does error still display?
No
Shut off power supply and rotate fan by
hand. Does fan spin freely?
Yes
The unit operates
normally.
Check the wiring of the fan motor. Is it
connected correctly?
Yes
Measure the voltage for the fan motor
from the main PCB. Is the voltage cor
-
rect?
Yes
Replace the electric control box.
Yes
No
Remove obstruction.
No
Correct the
connections.
No
Replace the main PCB
Yes
Replace the fan motor
No
1.
Indoor DC fan motor (Control Chip is in Fan
Motor)
2.
Turn power on and while the unit is on standby,
measure the voltage between pin1 and pin3
as well as between pin4 and pin3 in fan motor
connector. If the value of the voltage is not within
the range shown in the following table, the PCB
may be experiencing problems and need to be
replaced.
DC Motor Voltage Input and Output
NO.
Color
Signal
Voltage
1
Red
Vs/Vm
200~380V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
13.5~16.5V
5
Yellow
Vsp
0~6.5V
6
Blue
FG
13.5~16.5V
Summary of Contents for MWMA009S4-*L
Page 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Page 118: ...118 Error Code P1 continued ...
Page 120: ...120 Error Code P2 continued ...
Page 122: ...122 Error Code P3 continued ...
Page 144: ...144 Error Code P0 continued P U P V ...
Page 145: ...145 P W P N ...
Page 151: ...151 Error Code P6 continued ...