MPA Multi-Zone Specifications Outdoor Units (3 - 4 Ton)
Nominal Size - Tons
3
4
Outdoor Unit Model No.
MPA036S4M
MPA048S4M
Number of Zones
Up to 4
Up to 5
1
AHRI Ratings
System Type
Ducted
Non-Ducted
Ducted
Non-Ducted
Cooling - Btuh
34,000
36,000
42,000
42,000
High Temperature Heating - Btuh
36,000
36,000
51,000
49,000
Low Temperature Heating - Btuh
24,400
23,400
31,800
31,200
SEER
15.00
18.00
18.00
20.00
EER
8.20
8.80
11.00
12.50
HSPF (Region IV)
9.3
10.0
9.5
10.0
AHRI Reference Number
8129615
8129614
8129617
8129616
Energy Star
No
No
No
Yes
Ambient Temperature Range - °F
Cooling
5 - 122
5 - 122
Heating
–13 - 76
–13 - 76
Sound Data (dBA)
Cooling
62
58
Heating
64
62
Refrigerant
Charge furnished (R-410A)
7 lbs. 15 oz.
9 lbs. 8 oz.
Maximum line length with furnished charge (per zone) - ft.
25
25
Additional charge required per ft. - oz.
0.161
0.161
Compressor
No. and Type
Twin-Rotary
Twin-Rotary
Refrigerant oil type
FV50S
FV50S
Refrigerant oil charge - oz.
36.2
47.3
Connections - in.
Gas+Gas pipe (flare)
(4) 1/4 + (3) 3/8 + (1) 1/2
(5) 1/4 + (3) 3/8 + (2) 1/2
Maximum length for all rooms - ft.
197
246
Maximum length for one indoor unit - ft.
98
98
Maximum height
difference between
indoor unit and outdoor
unit
Outdoor unit
above
than indoor
unit - ft.
33
33
Outdoor unit below than indoor
unit - ft.
49
49
Maximum difference in level between indoor units - ft.
33
33
Outdoor
Fan
(No.) Diameter - in.
(1) - 22
(2) - 20
Total air volume - cfm
2240
(2) 4240
rpm
950
(2) 800
Outdoor Coil
Number of rows
2.6
2
Fins per inch
15
15
Fin type
Hydrophilic aluminium
Tube outside diameter - in.
5/16
5/16
Tube type
Rifled copper tubing
Net face area - ft.
2
6.42
14.33
Design Pressure
PSIG
550/340
550/340
Shipping Data
Net/Shipping weight (lbs.)
162 / 174
218 / 245
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase
208/230V
208/230V
2
Maximum Overcurrent Protection (amps)
45
50
3
Minimum circuit ampacity
30
35
Compressor Rated load amps
19.5
22
Outdoor Fan Motor
Rated load amps
1.30
(2) 0.9
Output - W
120
(2) 85
NOTE - Per AHRI, the certified ratings for systems are valid for
all
combinations of indoor units with the specific outdoor units listed above and in the AHRI Directory of
Certified Equipment. Please visit
for further details and latest updates.
1
Ratings are AHRI certified to AHRI Standard 210/240-2008;
• Cooling Ratings - 80°F dry bulb/67°F wet bulb entering indoor coil air and 95°F dry bulb/75°F wet bulb outdoor air temperature.
• High Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 47°F dry bulb/43°F wet bulb outdoor air temperature.
• Low Temperature Heating Ratings - 70°F dry bulb/60°F wet bulb entering indoor coil air and 17°F dry bulb/15°F wet bulb outdoor air temperature.
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Adaptors are furnished for the gas pipe connections:
036 - (3) 3/8 x 1/2 in. and (1) 1/2 x 3/8 in.
048 - (3) 3/8 x 1/2 in., (2) 1/2 x 3/8 in., (2) 1/4 x 3/8 in. and (2) 1/2 x 5/8 in.
Summary of Contents for MWMA009S4-*L
Page 113: ...113 Error Code E6 continued Two terminals of the inductor Inductor ...
Page 118: ...118 Error Code P1 continued ...
Page 120: ...120 Error Code P2 continued ...
Page 122: ...122 Error Code P3 continued ...
Page 144: ...144 Error Code P0 continued P U P V ...
Page 145: ...145 P W P N ...
Page 151: ...151 Error Code P6 continued ...