background image

Summary of Contents for LI009HI-380P432

Page 1: ...Split Air Conditioner Thank you for selecting LENNOX air conditioners Please read this manual carefully before operation and keep it for further reference OWNER S MANUAL LENNOX AIR CONDITIONERS...

Page 2: ......

Page 3: ...LI009HI 380P432 LI009HO 380P432 LI012HI 380P432 LI012HO 380P432 LI018HI 380P432 LI018HO 380P432 LI024HI 380P432 LI024HO 380P432...

Page 4: ...emote controller 15 Introduction for icons on display screen 06 Introduction for buttons on remote controller 07 Clean and maintenance Checked items before maintenance Installation notice Installation...

Page 5: ...reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information u...

Page 6: ...allation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications H...

Page 7: ...20cm separation distance will be maintained between the device excluding its handset and users Cet appareil est conforme aux limites d exposition au rayonnement RF stipul es par la FCC et l IC pour un...

Page 8: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Page 9: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Page 10: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 11: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 12: ...to the actual display If remote controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel a...

Page 13: ...tion 8 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp S...

Page 14: ...door unit is ON This indicator is not available for some models Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to djust fan blowing angle Cooling only unit...

Page 15: ...tor on indoor unit will change accordingly Temperature can t be adjusted under This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto Auto Medium speed Low...

Page 16: ...air conditioner receives this signal the air conditioner will blow fan automatically Press this button continuously more than 2s the main unit will swing back and forth from up to down and then loosen...

Page 17: ...the corresponding setting temperature after adjusted press Turbo button for confirmation 3 At this time 1hour will be automatically increased at the timer position on the remote control that are 2hou...

Page 18: ...controller blinks Press or button to adjust TIMER ON setting After each pressing or button TIMER ON setting will increase or decrease 1min Hold or button 2s later the time will change quickly until re...

Page 19: ...and set temperature Under heating mode indoor fan operates at notch 3 speed or quiet mode according to the comparison between indoor ambient temperature and set temperature Under dry fan mode indoor...

Page 20: ...ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperature display is not available for some models At...

Page 21: ...and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If 8 Under temperature display the remote controller will display 46 heating heating fu...

Page 22: ...eries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operation point the remote contr...

Page 23: ...nting bracket for outdoor unit is damaged or corroded If yes please contact dealer The filter should be cleaned every three months If there is much dust in the operation environme After removing the f...

Page 24: ...plug WARNING When below phenomenon occurs please turn off air conditioner and disconnect power immedi ately and then contact the dealer or qualified professionals for service Air switch trips off or...

Page 25: ...ous safety accident WARNING sure that the unit is running in cooling mode Then fully close the valve at high pressure side liquid valve About 30 40 seconds later fully close the valve at low pressure...

Page 26: ...ight or strong wind The grounding resistance should comply with Including an circuit break with suitable capacity please note the following table Air switch should be included magnet buckle and heatin...

Page 27: ...y t e f a s t n a v e l e r e k a t d n a sures when opening the hole rear right 20 1 Please refer to the actual circumstances for the number of screws and the position of screws The pipe can be led o...

Page 28: ...ue N m NOTE Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided All wires of indoor unit and outdoor unit should be If the le...

Page 29: ...e actual one indoor outdoor wall pipe sealing gum Step 8 Bind up pipe 1 make them pass through the wall hole Hang the indoor unit on the wall mounting frame Stuff the gap between pipes and wall hole w...

Page 30: ...han 20cm For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capac...

Page 31: ...curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room During heating operation the condensate and defrosting water should be drained out reliably through...

Page 32: ...ng to the following requirement after finishing installation Possible malfunction The unit may drop shake or emit noise Connect the charging hose of piezometer to the Is water drained well It may caus...

Page 33: ...pipe The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging...

Page 34: ...ut on the indoor connection NOTICE Working temperature range 09K Check the quality of expanding port If there is any blemish expand the port again according to the steps above Expand the port with exp...

Page 35: ......

Page 36: ...OWNER S MANUAL Split Air Conditioner 66139900831...

Reviews: