Indoor
outdoor
5-10
2.
rear left
cut off
3.
the hole
2.
2.
2.
3.
3.
N
OTE
●
pipe joint
union nut
pipe
Φ55
Φ70
Step 2:
Install wall-mounting frame
Outlet pipe
right
1.
Step 4:
Step 1:
Choose installation location
Recommend the installation location to the client
and then confirm it with the client.
Hang the wall-mounting frame on the wall; adjust
it in horizontal position with the level meter and
then point out the screw fixing holes on the wall.
1.
Step 3:
Open piping hole
Drill the screw fixing holes on the wall with im-
pact drill(the specification of drill head should
be the same as the plastic expansion particle)
and then fill the plastic expansion particles in
the holes.
Step 5:
Connect the pipe of indoor unit
1.
Fix the wall-mounting frame on the wall with
tapping screws and then check if the frame
is firmly installed by pulling the frame. If the
plastic expansion particle is loose, please
drill another fixing hole nearby.
Installation of indoor unit
wall-mounted frame, shown as below.
N
OTE
left
right
left
Aim the pipe joint at the corresponding
rear right, left or rear left.
bellmouth.
Pretighten the union nut with hand.
Pay attention to dust prevention
-
a
e
m
y
t
e
f
a
s
t
n
a
v
e
l
e
r
e
k
a
t
d
n
a
sures when opening the hole.
rear right
20
1.
Please refer to the actual circumstances for the
number of screws and the position of screws.
The pipe can be led out in the direction of right,
Choose the position of piping hole according
Adjust the torque force by referring to the
wrench on the union nut. Tighten the union
nut with torque wrench.
to the direction of outlet pipe. The position of
piping hole should be a little lower than the
When installation is finished, pull the mounting
plate with hand to confirm whether it is fixed
tightly. The force distribution for all screws
should be uniform.
Open a piping hole with the diameter of
Φ
55
or
Φ7
0 on the selected outlet pipe position.
In order to drain smoothly, slant the piping
hole on the wall slightly downward to the
outdoor side with the gradient of 5-10°.
When select leading out the pipe from left or
right, please cut off the corresponding hole on
the bottom case.
union nut
torque wrench
pipe
indoor pipe
open-end
wrench
The wall panel is for illustrative purposes only,
please refer to the actual installation.
following sheet. Place the open-end wren-
ch on the pipe joint and place the torque
Wall
Wall
(Rear piping hole)
(For some models)
(Rear piping hole)
Space
to the
wall
above
150mm
Left
Space
to the
wall
above
150mm
Right
Mark in the middle of it
Level meter