Page 8
BLOWER DATA
SL280UH090V48B BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1280
1410
+18%
1220
1340
+12%
1155
1270
+6%
1095
1205
Factory Default
1035
1135
–6%
970
1070
–12%
910
1000
–18%
845
930
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
640
900
1015
1175
1005
1295
1500
1670
Factory Default
570
780
930
1040
895
1160
1345
1500
–
530
700
810
955
795
1050
1210
1405
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 380 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 380 cfm.
SL280UH090V48B BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
34
54
68
85
102 120
142 159 177 79 107 133 148 172
201
226 253 274 301 327
Med-Low 64
85 105 124 145 166 186 206 227 151 179 214 247 276 312 339 370 399 433 464
Med-High 85
112
135 157 184
208
233 258 284 230 261 305 348 379 421 453 490 523 565 602
High
110
139 172
201
234 270 294 326 352 478 369 414 462 506 547 597 643 691 735 781
Factory Default
Cooling
Speed
Low
30
46
59
77
87 106
118
143 152 70
93 115 134 153 172 195 219 242 260 286
Med-Low 36
56
76
95
120
136 162 175 196
100
132 163 192 214 244 276 307 338 368 402
Med-High 64
88
106 130 149 173 198
222
238 166 192 231 266 303 342 370 410 444 462 493
High
87
118
141 161 194 223 248 275 302 245 273 333 365 396 432 460 503 546 579 635
– Setting
Cooling
Speed
Low
28
43
53
70
83
97
110 120
135 53
72
88 112
133 150 175 191 205 230 245
Med-Low 37
56
72
86 106 124 141 158 176 84
111
134 154 185 215 235 260 284 311 336
Med-High 51
69
90 109 129 152 168 187 205 119 152
182 210
244 276 307 338 370 401 432
High
71
94 119 138 158
181
207 233 250
180 211
248 284 316 355 385 419 450 487 521