BLOWER DATA
SL280UH090V60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR, RETURN AIR FROM BOTH SIDES OR RETURN AIR FROM BOTTOM AND ONE SIDE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1420
1565
+18%
1355
1490
+12%
1285
1415
+6%
1215
1335
Factory Default
1145
1260
–6%
1080
1185
–12%
1010
1110
–18%
940
1035
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
1110
1205
1420
1680
1575
1740
2000
2305
Factory Default
1005
1100
1280
1545
1440
1595
1820
2125
–
890
1015
1125
1380
1295
1450
1610
1930
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 450 cfm.
SL280UH090V60C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
89 113 136 159
182
204
228
251 275
218
245 291 327 372 398 436 474 505 532 579
Med-Low 104 133 163 184 214 245 266 304 328 298 333 382 412 450 488 541 576 612 648 681
Med-High 162 191 227 262 294 333 354 391 422 440 476 527 576 636 686 741 777
820
857 892
High
279 316 355 394 432 473 509 547 584 772
808
877 946
1000
1056 1089 1146 1190 1255 1266
Factory Default
Cooling
Speed
Low
70
92
108
134 159 174 196 215 242 160 195
228
265 291 340 364 397 442 469 500
Med-Low 89 115 135 156 185 207 227 250
281
241 267 305 347 384 413 445 477 519 542 573
Med-High
122
149 183 206 234 269 297 324 350 330 370 414 452 500 542 593 634 675 702 747
High
214 241 277 318 350 388 423 449 469 553 591 655 713 781 819 868 922 967 1026 1066
– Setting
Cooling
Speed
Low
54
70
91
110
129 154 166 185
200
107 151 177 206 245 272 298 332 398 423 449
Med-Low 73
94
112
135 151 175 189 214 235 173
201
244 272 304 337 368 393 437 465 498
Med-High 93
120
141 160 191
221
244 261
288
246 271 310 353 395 433 466 492 528 557 593
High
149 185 217 251 284 314 352 386 422 410 456 505 543 595 635 692 729 777 829 867