BLOWER DATA
SL280UH110V60C BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR
− Air volumes in
bold
require Optional Return Air Base
and
field fabricated transition to accommodate
20 x 25 x 1 in. air filter in order to maintain proper air velocity.
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm
Second Stage Heating Speed - cfm
+24%
1640
1805
+18%
1560
1715
+12%
1480
1630
+6%
1400
1545
Factory Default
1325
1455
–6%
1245
1370
–12%
1165
1280
–18%
1085
1195
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm
Second Stage Cooling Speed - cfm
Low
Medium-Low Medium-High
2
High
Low
Medium-Low Medium-High
2
High
+
1020
1160
1285
1550
1505
1690
1855
2125
Factory Default
940
1050
1155
1400
1375
1525
1685
1935
–
835
945
1020
1250
1235
1380
1505
1730
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
2
Factory default setting.
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 450 cfm.
SL280UH110V60C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
Second Stage
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low
84 116 131 156 193 216 238 265 292
218
245 293 336 378 415 454 488 516 557 601
Med-Low 99
128
156 195 216 245
280
309 335 292 333 381 412 454 490 535 577 618 662 704
Med-High
128
157 193 226 266 293 321 360 387 373 412 475 518 573 617 661 710 771
800
857
High
238 274 303 354 388 413 460 493 524 675 717 786 854 898 983 1017 1071
1112
1157 1186
Factory Default
Cooling
Speed
Low
73
96
121
140 154 184 206
228
255 166 192 237 271 319 345 382 419 459 480 515
Med-Low
81 108
133 156 175 207 230 253 285
220
248 290 328 372 405 447 474 513 540 577
Med-High 92 123 148 185 209 246 277 302 331 290 328 374 415 452 487 536 576 605 653 701
High
175
202
247 285 327 364 388 426 457 477 511 590 647 690 739 789 843 901 947 998
– Setting
Cooling
Speed
Low
56
74
98 116 141 157 179 199 216 129 157 198
221
259 298 325 354 387 418 451
Med-Low 69
92
111
132 155 174 197 214 243 166 186 232 268 289 339 365 389 429 454 479
Med-High 78 107
128
149 172 203 230 249 278 204 225
282
312 353 383 406 452 489 519 552
High
124 157 186
220
261 291 321 352 386 326 372 427 464 526 566 608 658 706 762
808