background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

HORIZONTAL VENT

(Top Vent

 Application)

VERTICAL VENT

(Top Vent

 Application)

RECESSED

INSTALLATION

TOP VENT INSTALLATIONS

HORIZONT AL VENT 

(T op V ent 

 Application) 

VER TICAL VENT 

(T op V ent 

 Application) 

RECESSED 

INST ALLA TION 

TOP VENT INSTALLATIONS

CROSS CORNER

APPLICA

TION

FLA

T

APPLICA

TION

ROOM DIVIDER

APPLICATION

FLA

T ON W

ALL

APPLICA

TION

ISLAND

APPLICA

TION

Top View

Figure 3 - Typical Installation

LOCATION

In  selecting  the  location,  the  aesthetic  and 

functional  use  of  the  appliance  are  primary 

concerns.  However,  vent  system  routing  to 

the exterior and access to the fuel supply are 

also important.

Due  to  high  temperatures,  the  appliance 

should be located out of traffic and away from 

furniture and draperies (Figure 3). 

En raison des températures élevées, l’appareil 

devrait être installé dans un endroit où il y a 

peu de circulation et loin du mobilier et des 

tentures (Figure 3).

The location should also be free of electrical, 

plumbing  or  other  heating/air  conditioning 

ducting.

These  direct-vent  appliances  are  uniquely 

suited for installations requiring a utility shelf 

positioned directly above the fireplace. Utility 

shelves like these are commonly used for locat-

ing television sets and decorative plants.

Be  aware  that  this  is  a  heat  producing  ap-

pliance.  Objects  placed  above  the  unit  are 

exposed to elevated temperatures.

Do not insulate the space between the ap-

pliance and the area above it (see 

Figure 8 

on Page 8)

.

The minimum height from the base of the appli-

ance to the underside of combustible materials 

used to construct a utility shelf in this fashion 

is shown in 

Figure 8 on Page 8

.  

The  appliance  should  be  mounted  on  a  fully 

supported  base  extending  the  full  width  and 

depth of the unit. The appliance may be located 

on or near conventional construction materials. 

However, if installed on combustible materials, 

such as carpeting, vinyl tile, etc., a metal or 

wood barrier covering the entire bottom surface 

must be used.

COLD CLIMATE INSULATION

For cold climate installations, seal all cracks 

around  your  appliance  with  noncombustible 

material  and  wherever  cold  air  could  enter 

the room. It is especially important to insulate 

outside chase cavity between studs and under 

floor on which appliance rests, if floor is above 

ground level.  Gas line holes and other open-

ings should be caulked or stuffed with unfaced 

fiberglass insulation.  

If the fireplace is being installed on a cement 

slab in cold climates, a sheet of plywood or 

other raised platform can be placed underneath 

to prevent cold transfer to the fireplace and into 

the  room.    It  also  helps  to  sheetrock  inside 

surfaces and tape for maximum air tightness 

and caulk firestops.

MANUFACTURED HOME 

REQUIREMENTS

This appliance may be installed in an aftermar-

ket permanently located, manufactured home 

and must be installed in accordance with the 

manufacturer's instructions and the Manufac-

tured Home Construction and Safety Standard, 

Title 24 CFR, Part 3280, in the United States, or 

the Standard for Installation in Mobile Homes, 

CAN/CSA Z240 MH Series, in Canada. 

Cet appareil peut être installé cómme du matéri-

el d'origine dans une maison préfabriquée (É.U. 

seulement) ou mobile et doit être installé selon 

les instructions du fabricant et conformément 

à la norme Manufactured Home Constructions 

and Safety, Title 24 CFR, Part 3200 aux Unis ou 

à la norme Can/CSA-Z240 Série MM, Maisons 

mobiles au Canada. 

This appliance is only for use with the type of 

gas indicated on the rating plate.  This appli-

ance is not convertible for use with other gases, 

unless a certified kit is used.

Cet appareil doit être utilisé uniquement avec le 

type de gaz indiqué sur la plaque signalétique.  

Cet appareil ne peut être converti à d'autres gaz, 

sauf si une trousse de conversion est utilisée.

CAUTION:  Ensure  that  the  cross  mem-

bers  are  not  cut  or  weakened  during 

installation.  The  structural  integrity  of 

the manufactured home floor, wall, and 

ceiling / roof must be maintained. 

CAUTION:  This  appliance  must  be 

grounded  to  the  chassis  of  the  manu-

factured home in accordance with local 

codes or in the absence of local codes, 

with the National Electrical Code ANSI / 

NFPA 70 - latest edition or the Canadian 

Electrical Code CSA C22.1 - latest edi-

tion.

Note:  

When the unit is installed with one side flush 

with a wall, the wall on the other side of the unit must 

not extend beyond the front edge of the unit.

f i r e - p a r t s . c o m

Summary of Contents for ADAGIO-EN

Page 1: ...isseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur...

Page 2: ...ssories that will require electrical power are to be installed the electrical power must be provided at the time of appliance installation The Electronic appliances have an electronic intermittent pil...

Page 3: ...Electrical Code CSA C22 1 latest edition Provide adequate clearances around air open ings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of th...

Page 4: ...edition NOTE Flame appearance will diminish 4 per thousand feet Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches Adagio 000 51 H0922...

Page 5: ...and wherever cold air could enter the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line ho...

Page 6: ...tional Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CSA B149 1 in Canada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccording to the installation cod...

Page 7: ...r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i...

Page 8: ...insulate the space between the appliance and the area above it Shelf Height see table Shelf Above Fireplace Top Vent Drywall Header Top Spacers 4 102mm u4 clearance is required above the elbow for ins...

Page 9: ...upport Thefireplaceshouldbesecuredtothesidefram ingmembersusingtheunit snailingflangeson each side of the fireplace front see Figure 11 Use 8d nails or their equivalent Figure 11 Left Side Front Corne...

Page 10: ...nce below the vent This does not include the suggested 1 4 rise per foot for horizontal runs With the facade installed required sold separately the appliancebasewillneedtobeelevatedaminimumof3 4 above...

Page 11: ...o change or discontinuance without notice With the facade installed required sold separately the appliance base will need to be elevated a minimum of 3 4 above the floor to allow for the proper fit of...

Page 12: ...sooting severe delayed ignition orothermalfunctions Anydamageresulting from an improper installation such as this is not covered under the limited warranty Never use galvanized or plastic pipe Refer...

Page 13: ...on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple ap pliances and must never be connected to a flue servingasolidfuelburningappliance The vent...

Page 14: ...5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0...

Page 15: ...of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer...

Page 16: ...ulk ing or mastic around the circumference of the joint to provide a water tight seal Figure 22 Storm Collar Flashing Figure 23 If the vent system extends more than 5 1 5 m above the roof flashing sta...

Page 17: ...VF uCeiling Firestop Spacer SV4 5VF u Ceiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4...

Page 18: ...nces for elbows as indicated in Figure 20 on Page 16 Maintain a minimum 1 25 mm clearance to combustibles on the vertical sections Clear ances for the horizontal runs are 3 76 mm on top 1 25 mm on sid...

Page 19: ...vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as describedinStepB Assembletheventsystem topointwheretheterminusofthelastse...

Page 20: ...1 V to 5 H ratio up to a maximum horizontal run of 20 feet except for installations where an elbow is the only vertical vent section in the system see Figure 30 AN ELBOW IS ACCEPTABLE AS 1 FOOT OF VER...

Page 21: ...f 20 feet An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system See Figure 30 V H H1 V1 Wall Firestop Spacer SV4 5HF Ceiling Firestop Spa...

Page 22: ...ck out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent...

Page 23: ...U P 2 1 N E E R G BLUE 20 BLACK 16 WHITE FIELD WIRED FACTORY WIRED Turn The Appliance Mounted ON OFF Burner Control Switch To The OFF Position If An Optional Control Switch Is Installed Optional Blowe...

Page 24: ...ns provided with the kit If the blower kit is to be installed at the time of installationoratalaterdate themainpowersup plyandwallswitchmustbeinstalledatthetimeof installation This will require that t...

Page 25: ...ions provided in the Care and Operation Manual For piezo igniter location see Figure 40 on Page 24 millivolt appliances only Note LightingInstructionsarealsofoundonthe literature tag tied to the gas p...

Page 26: ...installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appli...

Page 27: ...ole on the bottom of log D over pin 3 4 Place the right front log E as shown in Figure 47 Position the hole on the bottom of log E over pins 4 and 5 6 Ember Placement Separate the Embers rockwool into...

Page 28: ...ner when installing the door Take care when seat ing the top door gasket so that it is not obstructed by the refractory panel If the doorfeelsrestrictedwhenlatching thetop door gasket may not be prope...

Page 29: ...rod and associated adjustable air shutter is patented technology Flame ad justments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minut...

Page 30: ...equirements Wall Details Complete finished interior wall To install the appliance facing flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 54 u 4...

Page 31: ...ntrelasetiquetasadhesivasmultiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeel...

Page 32: ...750 247M Vent Sections ListedSecureFlex Components Cat No Model Description These termination kits include firestop spacer gear clamps and flex adaptor H1969 SF4 5HT 2 HorizontalSquareTermina tion wit...

Page 33: ...anufacturer s instructions and all applicable codes and requirementsoftheauthorityhavingjurisdiction Iftheinformationinthese instructionisnotfollowedexactly afire explosionorproductionofcarbon monoxid...

Page 34: ...t Orifice Thermopile on millivolt pilot assem blies only Millivolt Electronic Pilot Assemblies SIT Electronic Pilot Pilot Orifice B Retrieve the burner and slide the venturi tube over the orifice see...

Page 35: ...35 NOTES fire parts com...

Page 36: ...oducts reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fir...

Reviews: