background image

26

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Glowing Embers

Bag of Glowing 

Embers (rockwool)

Separate into Quarter 

Size (separate) Pieces

Locating Pins - 5 Places

Log Support Bracket

Firebox

Ember Burner Ports

LOG SET 

Catalog Number 

H1237

* Item

Description

A

Log, Rear

B

Log, Left Middle

C

Log, Right Middle

D

Log, Left Front

E

Log, Right Front

* Item "letters" above correspond to photos

D

C

A

B

E

Figure 43 - Log Set and Glowing Embers

Step 8. INSTALLING THE LOGS AND GLOWING EMBERS

A FIREBOX LINER KIT MUST BE INSTALLED BEFORE INSTALLING LOGS.  

THIS  APPLIANCE  IS  NOT  APPROVED  FOR  OPERATION  WITHOUT  A 

FIREBOX LINER KIT INSTALLED (SOLD SEPARATELY). SEE PAGE 15 

IN CARE AND OPERATION MANUAL FOR ORDERING INFORMATION. 

INSTALL LINER KIT AND LOG SUPPORT BRACKET PER INSTRUCTIONS 

PROVIDED IN KIT.
Locate log set carton and plastic bag of glowing embers. Refer to the Log 

Set Placement Instructions 

(Figures 43 to 49)

 for detailed placement 

instructions for the logs and glowing embers.
Proper log and ember placement is critical to encourage outstanding flame 

appearance and prevent sooting.  These fires are designed to provide a 

rich orange/red glow on the logs. 

Note: 

Log setup is by design asymmetric.  The fire is intentionally posi-

tioned off center to provide a natural fire look.

       WARNING

 

DO  NOT  attempt  to  install  the  logs  until  the 

appliance installation has been completed, the 

gas line connected and tested for leaks and the 

initial burner operation has been checked out.

 

The size and position of the log set was engi-

neered to give the appliance a safe, reliable 

and attractive flame pattern.  Any attempt to use 

a different log set in the fireplace will void the 

warranty and will result in incomplete combus-

tion, sooting, and poor flame quality. 

 

Logs get very hot and will remain hot up to one 

hour after gas supply is turned off.  Handle only 

when logs are cool.  Turn off all electricity to the 

appliance before you install logs and embers.

 

This appliance is not designed to burn wood.  

Any attempt to do so could cause irreparable 

damage to the appliance and prove hazardous 

to your safety.

 

If  logs  are  not  installed  according  to  the  log 

installation  instructions,  flame  impingement 

and improper combustion could occur and result 

in soot and/or excessive production of carbon 

monoxide  (CO),  a  colorless,  odorless,  toxic 

gas.

Complete the following before starting the log installation.

•  READ WARNINGS ON THIS PAGE BEFORE PROCEEDING

• 

Remove the front glass enclosure panel 

(see Glass Enclosure Panel 

Removal Instructions

Page 28

).

• 

Remove the log set from the firebox and the bag of embers from the 

control compartment.  Handle logs carefully to prevent breakage.

1

2

3

4

5

This appliance is provided 

with enough Glowing Em-

bers  for  several  applica-

tions, do not use all that is 

in a new bag at one time. 

For  best  glowing  effect, 

replace the ember material 

annually. 

f i r e - p a r t s . c o m

Summary of Contents for ADAGIO-EN

Page 1: ...isseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur...

Page 2: ...ssories that will require electrical power are to be installed the electrical power must be provided at the time of appliance installation The Electronic appliances have an electronic intermittent pil...

Page 3: ...Electrical Code CSA C22 1 latest edition Provide adequate clearances around air open ings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of th...

Page 4: ...edition NOTE Flame appearance will diminish 4 per thousand feet Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches Adagio 000 51 H0922...

Page 5: ...and wherever cold air could enter the room It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line ho...

Page 6: ...tional Fuel Gas Code ANSI Z223 1 in the USA or the current standards of CAN CSA B149 1 in Canada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccording to the installation cod...

Page 7: ...r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i...

Page 8: ...insulate the space between the appliance and the area above it Shelf Height see table Shelf Above Fireplace Top Vent Drywall Header Top Spacers 4 102mm u4 clearance is required above the elbow for ins...

Page 9: ...upport Thefireplaceshouldbesecuredtothesidefram ingmembersusingtheunit snailingflangeson each side of the fireplace front see Figure 11 Use 8d nails or their equivalent Figure 11 Left Side Front Corne...

Page 10: ...nce below the vent This does not include the suggested 1 4 rise per foot for horizontal runs With the facade installed required sold separately the appliancebasewillneedtobeelevatedaminimumof3 4 above...

Page 11: ...o change or discontinuance without notice With the facade installed required sold separately the appliance base will need to be elevated a minimum of 3 4 above the floor to allow for the proper fit of...

Page 12: ...sooting severe delayed ignition orothermalfunctions Anydamageresulting from an improper installation such as this is not covered under the limited warranty Never use galvanized or plastic pipe Refer...

Page 13: ...on Page 2 These fireplaces must be vented directly to the outside The vent system may not service multiple ap pliances and must never be connected to a flue servingasolidfuelburningappliance The vent...

Page 14: ...5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0...

Page 15: ...of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer...

Page 16: ...ulk ing or mastic around the circumference of the joint to provide a water tight seal Figure 22 Storm Collar Flashing Figure 23 If the vent system extends more than 5 1 5 m above the roof flashing sta...

Page 17: ...VF uCeiling Firestop Spacer SV4 5VF u Ceiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4...

Page 18: ...nces for elbows as indicated in Figure 20 on Page 16 Maintain a minimum 1 25 mm clearance to combustibles on the vertical sections Clear ances for the horizontal runs are 3 76 mm on top 1 25 mm on sid...

Page 19: ...vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as describedinStepB Assembletheventsystem topointwheretheterminusofthelastse...

Page 20: ...1 V to 5 H ratio up to a maximum horizontal run of 20 feet except for installations where an elbow is the only vertical vent section in the system see Figure 30 AN ELBOW IS ACCEPTABLE AS 1 FOOT OF VER...

Page 21: ...f 20 feet An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system See Figure 30 V H H1 V1 Wall Firestop Spacer SV4 5HF Ceiling Firestop Spa...

Page 22: ...ck out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent...

Page 23: ...U P 2 1 N E E R G BLUE 20 BLACK 16 WHITE FIELD WIRED FACTORY WIRED Turn The Appliance Mounted ON OFF Burner Control Switch To The OFF Position If An Optional Control Switch Is Installed Optional Blowe...

Page 24: ...ns provided with the kit If the blower kit is to be installed at the time of installationoratalaterdate themainpowersup plyandwallswitchmustbeinstalledatthetimeof installation This will require that t...

Page 25: ...ions provided in the Care and Operation Manual For piezo igniter location see Figure 40 on Page 24 millivolt appliances only Note LightingInstructionsarealsofoundonthe literature tag tied to the gas p...

Page 26: ...installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appli...

Page 27: ...ole on the bottom of log D over pin 3 4 Place the right front log E as shown in Figure 47 Position the hole on the bottom of log E over pins 4 and 5 6 Ember Placement Separate the Embers rockwool into...

Page 28: ...ner when installing the door Take care when seat ing the top door gasket so that it is not obstructed by the refractory panel If the doorfeelsrestrictedwhenlatching thetop door gasket may not be prope...

Page 29: ...rod and associated adjustable air shutter is patented technology Flame ad justments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minut...

Page 30: ...equirements Wall Details Complete finished interior wall To install the appliance facing flush with the finished wall position framework to accommodate the thickness of the finished wall Figure 54 u 4...

Page 31: ...ntrelasetiquetasadhesivasmultiling es proporcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor o el termostato de pared quecontrolalachimenea verifiquequeel...

Page 32: ...750 247M Vent Sections ListedSecureFlex Components Cat No Model Description These termination kits include firestop spacer gear clamps and flex adaptor H1969 SF4 5HT 2 HorizontalSquareTermina tion wit...

Page 33: ...anufacturer s instructions and all applicable codes and requirementsoftheauthorityhavingjurisdiction Iftheinformationinthese instructionisnotfollowedexactly afire explosionorproductionofcarbon monoxid...

Page 34: ...t Orifice Thermopile on millivolt pilot assem blies only Millivolt Electronic Pilot Assemblies SIT Electronic Pilot Pilot Orifice B Retrieve the burner and slide the venturi tube over the orifice see...

Page 35: ...35 NOTES fire parts com...

Page 36: ...oducts reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fir...

Reviews: