DIAGNOSIS
menue
E-LINK D
6060 •
D
4060
31
Actors - Overview
Note!
See hydraulic plan "External supply system" in the operating
manual D 6060 / D 4060.
The following actors are included in the diagnosis:
Actors
D 6060
D 4060
Electr. tying
Fan
PU Stop
Valve B
Valve C
Valve S1 (main valve, bottom)
Valve S2 (direction valve 1)
Valve S3 (direction valve 2)
Valve S4 S5 (to hydraulic switch)
Valve S6 S7 (to support foot)
Valve S8 S9 (to bale extractor)
Valve S11 (to chute)
Valve S12 (hydraulic switch A4)
Valve S13 (hydraulic switch A2)
Valve S14 (hydraulic switch A1)
Valve S15 (hydraulic switch A)
: Channels in additional CAN module
Remark:
The chain lubrication pump is supplied with bower via the
switch box located in the tying mechanism area. Fan (blower)
and chain lubrication pump are diagnosable only together: In
diagnosis, any malfunction of the fan is indicated only, if e. g.
the broken wire is located between main switch box and fan
switch box. A broken wire between switch box/tying mechanism
area and fan or chain lubrication pump is not diagnosable, not
even if both consumers (fan and chain lubrication pump) are
defective.
If a fan or the chain lubrication pump does not work, this is in
most cases due to a blown fuse in the switch box/tying
mechanism area. Each fan is protected by a 10 A flat fuse (red),
the fan to which the lubricating pump is connected is protected
by a 15 A fuse (blue).