SETUP
menue
E-LINK D
6060 •
D
4060
21
CAN modules
Note!
To avoid operating errors: adhere to the following procedure
When the inquiry as to whether both CAN modules are to be
used is answered with "No" and subsequently with "Yes", the
inquiry "P
ROGRAMING NEW ADDRESS
?" will be displayed:
(Step 1) Actuate no further keys.
(Step 2) Restore old status: Switch off power supply on
switch box, Figure: 1.
If by mistake the inquiry "P
ROGRAMING NEW ADDRESS
?" is
answered with "Yes" (via the key <Pr>), both CAN modules are
given the same address, i.e. both CAN modules are addressed
by means of the same "name". As a result, the functions
controlled by the renamed CAN module are no more available.
If this happens:
(Step 3) Switch power supply on switch box off and on
again (Figure: 1). The system starts anew.
After switching-on again, the message "CAN
MODULE
#
XY IS
MISSING
" is displayed. If this error message does not appear,
the CAN modules can be checked as described under steps 10
to 14.
(Step 4) Disconnect CAN module #2 from control system by
pulling the plug (in the switch box). Ignore any error
message "CAN
MODULE
#
XY IS MISSING
" which might occur,
and acknowledge with key <
>.
(Step 5) In the Setup on page 2/2, set "CAN module 1" from
"N
O
" to "Y
ES
": key <
>.
Answer the inquiry "P
ROGRAMING NEW ADDRESS
?" with
"Y
ES
". If CAN module 1 had already been set to "Y
ES
", it
must first be set to"N
O
".
CAN module addressing is finished after a few seconds.
(Step 6) Reconnect plug of module 2 and remove plug of
module 1, and proceed with module 2 – as described under
steps 4 and 5.
(Step 7) Ignore and acknowledge any error messages
possibly appearing during this process.
(Step 8) Reconnect CAN module 1.
(Step 9) Switch power supply on switch box off and on
again (Figure: 1). The system starts anew.