SETUP menue
22
E-LINK
D
6060 •
D
4060
If 10 seconds after the new start
no CAN error message
is
displayed, you can assume that both CAN modules work
correctly again. This can be tested as described in steps 10 to
14.
If a
CAN error message
appears, the procedure must be
repeated beginning with step 3.
When module x is to be addressed, the plug of module y must
be pulled. When module y is to be addressed, the plug of
module x must be pulled.
To test the CAN modules steps 10 to 14 must be carried out:
(Step 10) In the "Actors" diagnosis, go to page 2/2 (valves
1, 2, 3, 11, 12, 13, 14, 15).
(Step 11) Activate automatic diagnosis by means of the key
<
> (START/STOP).
If some or all valves do not switch, a CAN module is not
correctly addressed.
(Step 12) Address both modules once again anew
(beginning with step 3).
If all valves switch correctly, it is possible that the CAN modules
were exchanged by mistake during new addressing.
(Step 13) In the " Digital sensors " diagnosis, go to page
3/4.
(Step 14) Test with the keys for the chute and the bale
extractor.
If closing of the keys is correctly indicated in the diagnosis,
addressing has been successfully finished. If the key changes
are not correctly indicated, the two modules have been
exchanged and must be addressed anew (beginning with step
3).