6.6
Telephone connection
The colour of the indicator LED changes to orange during telephone connection.
6.6.1
Dial up time-out
EasyAlarm® tries to get in contact with called party for one minute (Profile P00) or two minutes (Profile P02/03/04). During
this time-out the Individual message will be announced periodically (P00) until the called party accepts call by sending
1
or just once if dial tone is present (P02/P03/P04)
green lamp “speak”on sub-communication unit is activated.
Note:
Adjust dial-up time-out
6.6.2
User announcement
User announcement is made up of
Notes:
Adjust user announcement
At the beginning of any phone connection battery state and main voltage are checked. In case of a problem an
appropriated message will be announced.
6.6.3
Connection time-out
If the call is accepted or extended by sending
1
or
3
the connection time-out will be 4 minutes.
10 seconds before time-out there will be a warning .
Connection time-out can be renewed by sending touch-tone
1
or
3
for another 4 minutes.
6.6.4
Touch-tone commands during telephone connection
Touch-tone DTMF Every valid command will be signalled
#
Announcement of PIN-Code (i.e. to identify elevator location)
0
Terminate telephone connection and acknowledge alarm
1
Switching to hands-free mode and restart connection time-out (4 minutes) and activate green lamp
EN81-70 on the sub-communication unit
2
Repeat announcements (Individual message / Cause of alarm)
3
Uphold telephone connection (4 minutes) and activate green lamp EN81-70 on the sub-
communication unit
4
Deactivate output (i.e. "Help is coming"
5
Announcement of current supervision mode as well as condition of the output
6
Activated output LMK-OUT (i.e. "Help is coming"
7
DISARM: Deactivate power-failure- and Sensor-1-monitoring temporarily.
8
During alarm connection: Terminate telephone connection and pass on alarm to next party in
calling number sequence
If no alarm is active: Start test call towards calling number 8
9
ARM: Re-activate power-failure and Sensor-1-monitoring
**0
Announcement of calling number sequence After the announcement you are able to re-program
the calling number
**
<n>
Announcement of calling number <n>
(
<n>
=
1
to
9
)
**##
Record individual message
**#0
Deactivate routine call
**#1
or
**#1
<h>
Activate routine. If left blank
<h>
, first routine call start after the programmed time-out
Start first routine call after
<h>
-hours. Follow-up calls in the time interval
**#2
Start routine call once without any delay
6.6.5
Service connection
In service mode the microphone and the loudspeaker remains inactive. This connection mode is used for technical alarms
(Sensor-1, Sensor-3, power failure, routine call and test call). By sending touch-tone
1
you may switch to hands-free
connection. If you change to hands-free connection three rings will alert a person inside the cabin for coming situation.
15
„Individual announcement”
to stop press
0
, to speak press
1
Cause of alarm
Abort