Welding wedge position factory setting
G.
In clamped confi guration and with the
set welding force, fi rst screw the
lower
contacting system (15)
with the
lower
contacting system adjusting screw
(20)
and then the
upper contacting
system (14)
with the
upper contac-
ting system adjusting screw (19)
in
the direction of the
welding wedge (5)
until the test strips are clamped lightly
in place.
14
5
15
20
19