45
Function and working display
Symbol
Meaning
Drive speed [m/min / ft./min]
Drive speed blocked [m/min / ft./min]
Welding wedge temperature [°C/°F]
Welding force [N/lbs]
Information box
Devices in Standby mode. The heating is switched off after the counter runs
through.
An error has occurred. An error code also appears
(the device is no longer ready for use). Contact an authorized service center.
See Chapter "Warnings and Error messages"
Warning:
See Chapter "Warnings and Error messages"
380
160
°C
The arrow pointing upward and the progress bar indicate that the setpoint
(shown on the progress bar) has not yet been reached (too cold). The fl ashing value
is the actual value. The value next to the progress bar is the setpoint.
390
°C
380
The arrow pointing downward and the progress bar indicate that the setpoint
(shown on the progress bar) has not yet been reached (too hot). The fl ashing value
is the actual value. The value next to the progress bar is the setpoint.
385
°C
380
If "Show Set Values" is activated, both the actual temperature (large font size) and
the set temperature (small font size) are displayed. Default setting ex-works.
°C
380
If "Show Set Values" is deactivated, then only the actual values (large) are dis-
played during operation, otherwise only the setpoint values (large).
Function display (34)