23
Only available with advanced functions Advanced Mode.
The unit system of the machine as well as the lighting of the
control panel (3)
can be
set here.
Unit: Uniform setting of the unit system (metric/imperial) for drive speed, hot-wedge
temperature and joining force
Unit Speed: individual setting of the unit used (metric/imperial) for drive speed
Unit Heat: individual setting of the unit used (metric/imperial) for hot-wedge temperature
Unit Force: individual setting of the unit used (metric/imperial) for joining force
LCD Contrast: Adjust the contrast of the display
LCD backlight: Adjust the backlight of the display
Key Backlight: Adjusting the background illumination keyboard on the
Control panel (3)
Only available with advanced functions Advanced Mode.
Warnings are displayed on a case-by-case basis in the
status display (31)
. If there is
a warning pending, you can still continue to work largely without restrictions. The menu
Warnings indicates the type of malfunction.
Once the malfunction has been rectified, the entry disappears.
Only available with advanced functions Advanced Mode.
Under General Info you will find version information regarding the software in addition to
information regarding the date of production.
Only available with advanced functions Advanced Mode.
Under Duty Info you will find information regarding the runtime of your COMET 700.
Hours Drive: current running time of the drive
Hours Heating: current running time of the heating
Hours Machine: current running time of the machine
Day Distance: distance traveled since last reset (must be reset manually)
Total Distance: distance traveled since the device was put into operation
1. Select and confirm symbol Settings [
Function display (28)
,
e-drive (27)
]
2. Select and confirm Advanced Mode [Menu selection,
e-drive (27)
]
3. Turn
e-drive (27)
clockwise (Advanced Mode 0) and confirm [Menu selection,
e-drive (27)
]
Disable advanced features
8.9. Machine Setup
8.8. Warnings
8.7. General Info
8.6. Duty Info