4.5
Batteries
4.5.1
Operating Principles
First-time use /
Charging batteries
• The battery must be charged prior to using it for the first time.
• The permissible temperature range for charging is between 0°C to +40°C/ +32°F to
+104°F. For optimal charging, we recommend charging the batteries at a low
ambient temperature of +10°C to +20°C/+50°F to +68°F if possible.
• It is normal for the battery to become warm during charging. Using the chargers
recommended by Leica Geosystems, it is not possible to charge the battery if the
temperature is too high.
• For Li-Ion batteries, a single refreshing cycle is sufficient. We recommend carrying
out a refreshing cycle when the battery capacity indicated on the charger or on a
Leica Geosystems product deviates significantly from the actual battery capacity
available.
Operation /
Discharging
• The batteries can be operated from -20°C to +55°C/-4°F to +131°F.
• Low operating temperatures reduce the capacity that can be drawn; high operating
temperatures reduce the service life of the battery.
4.5.2
Battery for the iCON robot 60/iCON builder 60 Instrument
Change battery
step-by-step
Reset...
Performs one of the following options:
•
Restart
(restarts Windows CE)
•
Reset Windows CE
(resets Windows CE and
communication settings to factory defaults)
•
Reset installed software
(resets settings of all
installed software)
•
Reset Windows CE and installed software
(resets Windows CE and settings of all installed
software)
Option
Description
Step
Description
1.
Face the instrument so that the vertical drive screw is on the left. The
battery compartment is below the vertical drive. Turn the knob to the
vertical position, opening the lid of the battery compartment.
2.
Pull out the battery housing.
006315_001
3
3
2
2
4
6