19
4 Settings and displays
4.3 Selecting the empty indicator
Press the button to select the empty
indicator.
Via agitator motor (1) with soft agitator,
via external empty indicator (2) - not
programmed
or
empty indicator switched off (0)
Empty ind. 1
One agitator
Press toggle switch: Setting saved, next
menu item
or
press main switch: Setting saved and
machine switched off.
4.4 Setting signal for electronic lifting gear control (EHR)
When the spreader is equipped with the headland manager accessory,
the hydraulic signal of the tractor can be detected. The signal is emitted
when lifting or lowering.
The spreader is set at the factory for the signal when lifting.
If the tractor emits the hydraulic signal when lowering, you can adjust the
spreader.
Press the button to set the EHR signal.
EHR signal for lifting:
High active
is displayed.
EHR signal for lowering:
Low active
is displayed.
EHR signal 0
High active
Press toggle switch: Setting saved, next
menu item
or
press main switch: Setting saved and
machine switched off.