OMEGA
Installation Manual
Edition Dec. 2004
Omega
platform lift
page 20 of 24
Mounting the control cams
•
Mount the control cams on the profiles between the upper and lower tube of the railway
in the area of the platform stop position.
•
Adjust the control cams - the levers for unclamping the barrier should be in the middle of
the control cams when the platform arrives in the stop position.
Note:
Mount the control cams according to the description on the layout drawing. Under
some circumstances, it may be necessary to unclamp both barriers in the lower stop
position. Use two control cams in this situation.
Caution:
Do not mount two control cams in the upper stop position
(or intermediate stop positions)!
•
Check the power functions on automatic type platforms. Or check the operations on the
manual platform.
•
Check each operation again for each landing in the system.
Mounting the ultimate limit switch
•
Adjust the mechanical limit
block so that it is properly
aligned with the sensor on the
cover of the upper carriage.
Adjust the ultimate limit
switch and the mechanical
limit block together!