49
_________________________________________________________________________________
13. TROUBLE
SHOOTING
Following table shows eventual failures and malfunctions of the access platform and the ways how to
repair them.
ISSUE
REASON
CORRECTIVE ACTION
Motor will not start when the
start button is pressed.
(combustion engine or electric
motor)
Emergency stop button is
active.
Ignition key switch is in
”0” -position or different control
position is selected.
Release all emergency stop
buttons.
Select correct control position.
Combustion engine does not
start when start button is
pressed.
(See also engine
m
anufacturer’s Operators
Manual.)
Motor is too cold.
Fuel tank is empty.
Empty start battery.
Burnt fuse.
Issue in fuel delivery.
Issue in air intake.
Start button broken.
Restart the engine, use
maximum glow time (see 5.1.1).
Refill (see 9.4).
Charge battery by connecting
230 V or use jumper cables
(option), replace battery if
necessary.
Replace fuse (see 0).
Check fuel tank, fuel lines, fuel
filter and fuel pump.
Clean air filter with compressed
air, replace if necessary.
Check wiring, replace button.
Electric motor does not start
when start button is pressed.
Mains cable is not connected to
network.
Empty battery.
Burnt fuse.
Start button broken.
Connect 230 V / 16 A wall
socket.
Charge battery by connecting
230V or use jumper cables
(option), replace battery if
necessary.
Replace fuse (see 0).
Check wiring, replace button.