26
_________________________________________________________________________________
5.6 Remote control (option)
Lower controls must be selected in order to operate the access platform remotely.
1. Select remote control with the remote control selection switch (Figure 6 (8)).
2. Lift remote control emergency stop button.
3. Start the remote (Figure 8 (3)).
4. Start the preferred motor (Figure 8 (6) or Figure 8 (7)).
5. Use drive or outrigger functions.
-
Drive with levers (Figure 8 (8)).
-
Outriggers can be controlled with either the automatic leveling switch (Figure 8 (2)) or
one at a time with individual control switches for the left-hand side (Figure 8 (4)) or for
the right-hand side (Figure 8 (5)).
6. To stop, turn off the motor in the corresponding switch and then the remote by pressing the
emergency stop button on the remote.
7. Place the remote in the dedicated enclosure
8.
Switch remote control selection switch to “0”.
9.
Switch ignition key switch to ”0”.
The remote emergency stop will only operate when the remote control is selected.
5.7 Ending the operation
After ending the operation:
1. Lower the booms down to transport position.
2. Lift the outriggers completely up to transport position.
3. Stop the combustion engine / electric motor by pressing the stop button of the motor.
4. Remove safety harnesses from the platform and take them with you (harnesses must be kept
in their place and in their box/package).
5. Turn the ignition key swit
ch to ”0” and take it with you.
6. If the machine stays in a place where it can be connected to 230VAC mains current, it is
recommended to leave it connected to charge the battery (e.g. overnight).
NOTE! Prevent unauthorized use of the lift by removing ignition key and main
disco
nnect switch from the machine when it’s not used!
5.8 Additional instructions for winter use
The minimum allowed operating temperature for the access platform is -20 °C.
Do the following actions during winter time:
-
Check that the limit switches are free from snow, ice and dirt.
-
If the ambient temperature is below +2 °C the manufacturer recommends to use a separate
engine heater (option).
-
Let the engine run for a few minutes before moving the machine.
-
First use drive mode for a while, then use outriggers and lastly use the booms. This way the oil
in the whole system heats up and warm oil flows to the cylinders.