DESCRIPTION AND OPERATION
The RT-200 is an astronomic time clock and timer switch that controls the connected light or fan either manually or through user
programmed times.
Upon installation the user enters the correct longitude/latitude coordinates, date, and local time. This ensures that once the schedules
are programmed, the load turns ON/OFF at the correct local times. The button switch is a customizable manual override feature with a
default countdown of 2 hours.
Lighted Switch
To help locate the switch button in a dark room, an amber LED illuminates the ON/OFF button while the controlled load is OFF. When
the load is ON, the LED is OFF.
INSTALLATION & WIRING
1.
Prepare the switch box
After the power is turned OFF at the circuit breaker box,
remove the existing wall plate and mounting screws. Pull the
old switch from the wall box.
2.
Identify the type of circuit
In a single pole circuit, two single wires connect to two screws
on the existing switch. A ground wire may also be present and
connected to a ground terminal on the old switch. A neutral
wire should also be present in the wall box.
3.
Prepare the wires
Tag the wires currently connected to the existing switch, so
that they can be identified later. Disconnect the wires. Make
sure the insulation is stripped off the wires to expose their
copper cores to the length indicated by the “Strip Gauge”
(approximately ½ inch).
SPECIFICATIONS
Voltage .....................................................120/277VAC, 50/60Hz
Load (Single Pole) ................ 0-800W tungsten or ballast, 1/6HP
Environment ...................................................... Indoor Use Only
Operating Temperature ..............
32˚ to 122˚ F (0˚ to 50˚ C)
Humidity ..................................... 95% RH, non-condensing
Countdown Options ........... none, 5 min, 10 min, 15 min, 30 min,
..............................1 hr, 2 hr (default), 3hr, 4 hr, 5 hr, or 6hr
Tools Needed
Insulated Screwdriver
Wire Strippers
Strip Gauge
1/2"
12.7mm
TOP
INDO
OR U
SE O
NLY
Green > GROUND
Terminal
Black > HOT (power
from circuit box)
Red > LOAD (power
to lamp or fan)
White > NEUTRAL
Industry standard
switch cover plate
(not provided)
WARNING
DISCONNECT POWER AT THE CIRCUIT BREAKER BEFORE INSTALLING THIS PRODUCT.
ONLY CONNECT THE RT-200 TO A SINGLE POLE CIRCUIT. THE RT-200 IS NOT SUITABLE FOR 3-WAY SWITCHING.
IF THE EXISTING WIRING DOES NOT MATCH THE DESCRIPTION FOR A SINGLE POLE
CIRCUIT, YOU SHOULD CONSULT WITH A QUALIFIED ELECTRICIAN.