1. Insert ON (GREEN) and OFF (RED) trippers
into dial at desired ON and OFF times.
2. Turn dial CLOCKWISE one or more
complete revolutions until the arrowhead is
aligned with time-of-day (AM or PM) in
window.
3. Turn lamp or appliance ON.
4. Plug extension cord, lamp or appliance into
timers receptacle and plug timer cord into
wall outlet, suitable for "wet locations" if outdoors.
FOR EARLY ON OR OFF OPERATION,
Turn manual knob counter clockwise
to desired ON or
OFF position, Timer will follow next scheduled automatic operation.
IN CASE OF POWER FAILURE, RESET TIMER, (SEE STEP 2)
WARNING: To avoid shock hazard, timer must be installed
VERTICALLY and at least 3 ft. ABOVE ground level. WATTAGE OF
LAMPS OR APPLIANCES BEING CONTROLLED SHOULD NOT
EXCEED CAPACITY OF TIMER. WHEN USED WITH EXTENSION
CORD OR DEVICES DO NOT EXCEED THEIR RATING OR 15 AMPS.
MODEL: HB31R
15 AMP (1800 WATT) RESISTIVE; 15 AMP
(1800 WATT) TUNGSTEN; 15 FLA (90 LRA) MOTOR-120 VOLT 60 HZ.
INTERMATIC INCORPORATED
154SB19358
LISTED
885L
LR3730
RAINTIGHT OUTDOOR TIMER
PROGRAM REPEATS EVERY 24 HOURS
TO SET TIMER: (SEE ILLUSTRATION)