Doc No. FM0600 issue I Page 9 

 

16. REGISTERING A SENSOR CONTROLLER ONTO A REACH AT-HOME ALARM 

 
1. Put the Reach unit into radio device learn mode… 
  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
2. Activate the sensor controller… 
 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 
 

 

  

 
 
 
 
 
 
 
3. Exit radio device learn mode… 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 

 

4. Check with the Control Centre that it is convenient to perform a test call, press the 

CARER CALL

 button and confirm they receive the 

correct alarm call type 

i.e. bed occupancy, chair occupancy or door exit

.  

 

 

Deleting a Sensor Controller from a

 

Reach 

at-home alarm unit

 

 

Enter 

 1 6 7 0

 using the keypad on the rear of the Reach unit – the front light will

 FLASH FAST GREEN

 and the unit will announce 

Program Mode - Ready

”. 

Enter 

# 0 4 1

 and the Reach will announce “

Delete Radio Device

” followed by a “

Beep

”. 

Enter the 8 digit sensor controller ID

 to be deleted; after the “

Beep

” press 

#

 to exit. 

Press the 

 

key to exit Program Mode; the unit will sound a “

Double-Beep

” and the front light will return to 

STEADY GREEN

.  

 

 

The 8 digit ID is made up of the 2 digit sensor type code e.g. bed sensor = 33, chair sensor = 38 or door exit = 34 followed by the 6 digit 

unit ID which can be found on a label on the back of the sensor controller.   

 
 
 

 

 

The instructions given above for the standard Reach product also applies to the Reach Plus, Reach Plus GSM 
and Reach Ultra models. Refer to the instruction booklets provided with these products for more information 
on programming and testing radio devices.  

  

 
 
 
 

 

Trigger 

Radio 

Device

 

Press and HOLD the 

GREEN

 

 

button on the Reach unit. 

 

When the front light 

FLASHES FAST GREEN

 

release the 

button

 

and the Reach will announce “

Trigger Radio Device

”. 

 

You now have 1 minute to activate the sensor controller. 
 

 

Press the 

GREEN

 

 

button on the Reach unit. 

 

The front light will return to 

STEADY GREEN

 

and the Reach 

is back in normal operating mode. 

 

Press the 

CARER CALL

 button and the Reach will announce the type 

of sensor that has been setup… 

 

a unit with a bed sensor will announce “

Bed Occupancy

” 

or 
a unit with a chair sensor will announce “

Chair Occupancy

” 

or 
a unit with a pressure mat or door contact will announce “

Door Exit

” 

 

Summary of Contents for Tynetec ZXT473

Page 1: ...d but they are OK then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their bed chair at the end of this period then an alarm will be raised agai...

Page 2: ...CONTROLLER The sensor controller includes a power lead and a rechargeable battery depending on the package it may also be supplied with either a bed sensor or a chair sensor Alternative bed chair sens...

Page 3: ...Spare Chair Sensor with 2m Lead Product Code ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Product Code P10285 4 HOW TO INSTALL A PRESSURE MAT The Pr...

Page 4: ...st be placed on top of the mattress below the sheet See the placement options printed on the Bed Sensor Ensure the connecting cable exits safely without causing a trip hazard Plug the lead into the se...

Page 5: ...another sub menu or give you the option to change settings Use the keys to increase decrease the setting highlighted by the cursor Use the keys to move the cursor back forwards between fields To retu...

Page 6: ...l end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use the keys to set the still in bed alarm from 0 to 999 minutes then press...

Page 7: ...Setup Exit Select Calibrate and Test then press ENTER Calibrate and Test Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test Test Mode Exit Calibrate Sensor place the bed chair s...

Page 8: ...d Alarm No Still in Bed Alarm No Low Battery Beep Yes Program ID to enter the last 6 digits from the product label Register Device to learn the unit onto an at home alarm warden call carer call or Nur...

Page 9: ...digit ID is made up of the 2 digit sensor type code e g bed sensor 33 chair sensor 38 or door exit 34 followed by the 6 digit unit ID which can be found on a label on the back of the sensor controller...

Page 10: ...Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for m...

Page 11: ...o FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press the CARER CALL button The display will show the Sensor Type and the sensor controller...

Page 12: ...leted from the Delete Telecare Device pull down list box prefixed with a T33 34 38 Details of the Sensor Controller selected will be displayed in the Room House Code and ID boxes below If the details...

Page 13: ...y can be used to raise an instant alarm call via the warden call system at home alarm or Nursecall system When the sensor controller is in its normal operating mode the key is used to send a CARER CAL...

Reviews: