Default setting:

600

(10 minutes).

 

Parameter size: 

4 [byte] 

 

Parameter No. 102 Setting time for sending meter report (KWh) 

The interval of sending meter report (KWh) to association device (Group Lifeline).

 

 

Available settings: 

5- 2678400 

(5 - 2678400s) 

- The function is disabled. 

 

Default setting:

3600

(one hours).

 

Parameter size: 

4 [byte] 

 

Parameter No. 103 Setting time for sending meter report (voltage) 

The interval of sending meter report (voltage) to association device (Group Lifeline).

 

 

Available settings: 

5- 2678400 

(5 - 2678400s) 

- The function is disabled. 

 

Default setting:

 0 

(disabled).

 

Parameter size: 

4 [byte] 

 

Parameter No. 104 Setting time for sending meter report (current) 

Summary of Contents for 6A-PL-VAB-C0

Page 1: ...perated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless...

Page 2: ...1xAC output 2 AC output switch on off by manual or Z Wave command 3 LED indicates the Z WAVE network range 4 LED indicates the load power 5 Supporting power meter 6 Supporting repeater role 7 Support...

Page 3: ...ulse withstand voltage 2 5KV Duty type S1 continuous duty Number of operating cycles 10000 CIRCUIT DISCONNECTION Micro disconnection Glow wire temperature 650 C Non replaceable built in protection the...

Page 4: ...ATION_GR P_INFO COMMAND_CLASS_MANUFACTURER_ SPECIFIC COMMAND_CLASS_DEVICE_RESET_LO CALLY COMMAND_CLASS_METER_V3 COMMAND_CLASS_SCENE_ACTIVATIO N COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SUPERVISION CO...

Page 5: ...MMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GR P_INFO COMMAND_CLASS_DEVICE_RESET_LO CALLY COMMAND_CLASS_CONFIGURATION_ V3 COMMAND_CLASS_METER...

Page 6: ...RY ROLE_TYPE_SLAV E_ALWAYS_ON 3 LED indicator mode Smart Plug s LED indicator supports two work modes including Power indication mode and night lamp mode Power indication mode Power indication mode wi...

Page 7: ...rk main controller into learning mode 2 Short press the Z button twice 3 The LED keep blink to the end of add inclusion If the add for inclusion is successful LED will turn on within 2 seconds and The...

Page 8: ...er into learning mode 2 Short press the Z button twice 2 The LED keep blink to the end of add inclusion If the add for inclusion is successful LED will turn on within 2 seconds and Then will be in pow...

Page 9: ...s twice 1 Smart Plug will send node info frame 2 Remove for exclusion 1 Set the Z Wave network main controller into removing mode 2 Short press Z button twice 3 The LED keep blink to the end of remove...

Page 10: ...econds to accelerate flash The reset successful will send Device_Reset_Locally to the main controller and exclude from the Z Wave network this procedure will reset Smart Plug to factory default 5 Note...

Page 11: ...mand such as short pressing 2 Sending Meter Report 2 Association Group Info Command Association Group Name Report Command Grouping identifier value Group 1 Lifeline ASSIC Code 4C 69 66 65 6C 69 6E 65...

Page 12: ...D_CLASS_DEVICE_RE SET_LOCALLY 0x5A DEVICE_RESET_LOCALLY_NOTI FICATION 0x01 5 2 Z Wave Plus Info Report Command Parameter value Z Wave Plus Version 1 Role Type 6 ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_A...

Page 13: ...ct Type ID 2 0x00 Product ID 1 0x00 Product ID 2 0x0b 5 4 Version Report Command Parameter Value HEX Z Wave Protocol Library Type 0x03 Z Wave Protocol Version 0x04 Z Wave Protocol Sub Version 0x3d Fir...

Page 14: ...eters can be accessed from main controllersconfiguration interface Parameter No 01 Overcurrent protection Smart Plug keep detecting the load power once the ACcurrent exceeds 16A for more than 5s smart...

Page 15: ...be off after the power supply isreconnected Default setting 0 Parameter size 1 byte Parameter No 03 Notification when Load status change Smart Plug can send notifications to associated device Group L...

Page 16: ...ts minimum change in wattage in terms of wattage for a meter report to be sent When the change value of load power exceeds the setting value smart plug will send meter report watt to associated device...

Page 17: ...he function is disabled Default setting 10 10 Parameter size 1 byte Parameter NO 100 Setting the parameters 101 104 to the default states Available settings 85 Default Setting 85 Parameter size 1 byte...

Page 18: ...0 5 2678400s 0 The function is disabled Default setting 3600 one hours Parameter size 4 byte Parameter No 103 Setting time for sending meter report voltage The interval of sending meter report voltage...

Page 19: ...he configuration command Lock unlock all configuration parameters 0 Unlock 1 Lock Default setting 0 Parameter size 1 byte Parameter No 255 Reset Smart Plug Reset the Smart Plug or remove from the Z Wa...

Page 20: ...The way to add for inclusion is different 1 1 Add for inclusion non security See the section of 5 Functions of each trigger above 1 2 Add for inclusion security See the section of 5 Functions of each...

Page 21: ...XINGDA RD XINGTAI INDUSTRIAL ZONE CHANGTAI COUNTY ZHANGZHOU FUJIAN 363900 CHINA...

Reviews: