14
www.leantechnik.com
6 Correct use
6 Correct use
See also Section 2.3
6.1 Instructions for use
•
Static application: - Hold and clamp in the event of
power failure - In case of pressure drop - EMERGENCY STOP
•
Observance of the correct dimensioning of the clamping force
and switching frequency during EMERGENCY STOP for safe
holding of the mass and safe adherence to the required
braking distance.
•
Use in a clean environment (penetration of lubricating greases,
coarse dust and other friction-reducing substances can
impair the clamping / braking function).
•
Use in closed buildings (in tropical regions, high
ambient humidity and temperatures below 0 °C with
long downtimes, in marine climates, only with special
measures).
6.2 Limitations
•
The brake is not suitable for use in heavily soiled
environments
•
The brake is not suitable for use in high ambient
temperatures >70 °C
•
The brake is not suitable for use in liquid media
•
The brake is not suitable for use in a vacuum
•
The brake not suitable for contact with abrasive media
(e.g. friction and grinding dust)
•
The brake is not suitable for contact with aggressive,
corrosive media (e.g. solvents, acids, alkalis,
salt, etc.)
•
The brake is not suitable for contact with foodstuffs
6.3 Reasonably foreseeable misuse
The following uses are prohibited and can lead to hazards.
•
Any opening of the screws on the housing.
•
Operation without profile rail.
•
Exceeding the specified maximum
operating pressure.
•
Changing the brake by means of additional
recesses, drill holes, etc.
6.4 Duration of use
20 years or after reaching T10d (definition see EN ISO
13849-1) service life.