Figure 19 Spindle output & analog output of the MX4660
The precision of the analog output is related to PWMBase Freq. parameter settings. When set PWMBase Freq. =
80 Hz, the precision/resolution reached to +/- 11.875 mV. See below.
Figure 20 PWMBase Freq. parameter settings & analog output precision