Hardware
installation manual of the multi-axis drive MX4660
Leadshine Technology Co., Ltd
Leadshine America, Inc.
Page 16/28
3/F, Block 2, Nanyou Tianan Industrial Park, Shenzhen, China
25 Mauchly, Suite 318, Irvine, CA 92618, USA
Tel: 86-755-26409254
Fax: 86-755-26402718
Tel: 1-949-608-7270
Fax: 1-949-608-7298
Web:
www.leadshine.com
Email:
Web:
www.leadshine.com
Email:
Figure 15
Home / limit switch connections to Input1-4 of the MX4660
Connecting the Digital Outputs
The digital Output Connections are optional.
The 6 general digital outputs are located at the Digital Output
Connector (Figure 3) of the MX4660, named as Output 1, Output 2, Output 3, Output 4, Output 5 and Output 6.
They can be used to control a DC relay for coolant in a CNC router, or for other purpose such as expanding the
5
th
and 6
th
axis.
Output 1 and Output2 are connected to Pin 17, 1 of the DB25 connector respectively, and Output 3, Output 4,
Output 5 and Output 6 are connected to Pin 17, 1, 8, and 9 of the 26-pin low profile connector respectively.
Connect one end of the load to “Output X+” (X can be 1, 2, 3, 4, 5, 6, 7 or 8) pin and the other end to the VDC+
of a 5-24VDC power source. Then, connect the related “Output X-” pin of MX4660 to the power supply VDC-.
Those digital outputs are rated at max 70mA. Refer to figure 21 of “MX4660 Connection Diagram” on page20 for
using high speed digital output to expand the 5
th
axis.
Notice that the maximum frequency of the
Output 1, Output 2, Output 3 and Output 4
is
200 kHz
, and that of
the
Output 3 and Output 4
is
20 kHz
.