EM3E Series EtherCAT Stepper Drive User Manual
34
5 Error Code & Trouble Shooting
When an alarm is occurred, the drive turns on the protection function and the motor stops
running. EM3E has three object dictionaries that can read alarm code, and two red LED lights
flash to display some of the alarm information.
5.1 Error Code
(1) Object 01 indicates the current failure alarm, and other sub-index indications are
historical alarms.
(2) Object 0x1001 and 0x603F indicate the current failure alarm, The error code read by
0x603F is IEC 61800 specification; the error code read by 0x1001 is CIA specification.
(3) Error code read by some master station is displayed in decimal. At this time, please convert
it to hexadecimal and then refer to the error code table as below. For example, the master
station reports error code of 8721, the corresponding hexadecimal number is 0x2211, so the
alarm information in the reference table is over-current alarm.
Error code table:
0x3FFE
0x603F
Description
Trouble Shooting
0x0e0
0x2211
Over-current
1. Check whether the wiring is short-circuited, or
the motor is short-circuited.
2. Switch power supply alarm caused, replace other
power supply for a try.
0x0c0
0x3211
Over-voltage
1. Check the voltage of power supply;
2. If over-voltage occurs in motion, the acceleration
and deceleration time can be increased
0x0a0
0x3150
EEPROM error in phase A
1. Reset parameters to the factory and restart
power supply
2. If it still exists,the hardware failure
0x0a1
0x3151
EEPROM error in phase B
0x1a0
0x8402
Over-speed
1. Reduce command speed value;
2. Write 0x10 to the object 0x2056 to clear the
alarm.
0x240
0x5530
Save error
1. Reset parameters to the factory and restart
power supply
2. If it still exists,the hardware failure
0x260
0x7329
Limit switched alarm
Refer to 00
0x570
0x5441
Quick stop alarm
Refer to 00
0x5f0
0x7122
Auto-tuning error
1. Restart the drive;
2. If it still exists,disable auto-tuning by 0x2013
0x816
0x8216
Invalid mailbox configuration
in pre-operation state
Check the network cable
0x81b
0x821B
Watchdog timeout
Check the network cable
0x836
0x8736
Invalid
DC
synchronization
period
Decrease the value of the synchronization period
or increase the value of 02
0x870
0x5201
Unsupported operation mode
Check the value of 0x6061 and correct it to the
supported operation mode;
0x801
0x8201
ESM state machine transition
failed
Alarms related to the master station, without
accurate solution.
0x802
0x5510
Memory overflow
0x807
0x8207
The mapping object does not
exist
0x808
0x8208
PDO mapping object
length
error
0x809
0x8209
PDO mapping object has no
mapping attribute
0x811
0xA001
Invalid
ESM
conversion
request
0x812
0xA002
Unknown
ESM
conversion
request