EM3E Series EtherCAT Stepper Drive User Manual
23
4.2 Manufacture Specific Object
Inde
x
Sub-
inde
x
Name
Access
Type
Range
Defaul
t value
Unit
Remark
2000
00
Peak current
R/W/S
DINT
100-7000
1000
mA
Drive's max output current.
2001
00
Microstep
resolution
R/W/S
DINT
200-51200
10000
Puls
e
Required number of pulse to
rotate 1 revolution of motor
2007
00
Action
when
disabled
R/W/S
UINT
0-1
0
-
0:
Don't
respond
to
commands, and the motor
shaft is not locked;
1:
Don't
respond
to
commands, but the motor
shaft is locked;
2010
01
Internal
filtering
time
R/W/S
UINT
0-32767
100
0.1m
s
Internal smoothing time for
control command.
2012
00
Soft-starting time
R/W/S
UINT
10-3000
1
ms
Internal smoothing time for
starting current.
2013
00
Auto-tuning
at
power on
R/W/S
UINT
0-2
1
--
1: Yes. 0: No
201A
01
Locking
current
percentage
of
power on
R/W/S
UINT
0-100
100
%
Usually keep the default
value.
201B
00
Locking
duration
time
R/W/S
UINT
0-1500
200
ms
Appropriately reduce this
value if you want to shorten
the time of locking shaft.
201C
00
Max time to close
brake
R/W/S
UINT
100-10000
1000
ms
Usually keep the default
value
201D
00
Zero speed point
R/W/S
UINT
0-500
10
0.1r/
s
-
2047
00
Over voltage point
R/W/S
UINT
0-1000
75
V
EM3E-870E is 120V
2048
00
Bus-voltage
R
UINT
0-65535
-
V
-
2051
00
Motor
running
direction
R/W
DINT
0-255
0
--
Valid when 0x225C= 0;
0: CCW direction
1 or 4: CW direction
2056
00
Alarm
detection
selection
R/W/S
DINT
0~65535
65535
--
Bit setting:
=1: Yes; =0: No
Bit0: over-current (invalid)
Bit1: over-voltage
2090
01
Current loop Kp
R/W
DINT
0~32767
1500
--
--
02
Current loop Ki
R/W
DINT
0~32767
300
--
--
03
Current loop Kc
R/W
DINT
0~32767
300
--
--
2150
00
Slave ID
R/W/S
UINT
0-256
1
--
Valid when 0x2151= 1;
2151
00
Slave ID resource
R/W/S
UINT
0-10
0
--
0: DIP switches
1: Setting by 0x2150
2: ESC
2232
00
Synchronous
compensation1
R/W
DINT
0—65535
2
-