2. ETHERNET
8
●
DATE&TIME
LV 5800 (MULTI MONITOR)
Command Parameter1
Description
YYYY/MM/DD,hh:mm:ss
Sets up the date and time.
SYS:DATE
?
Queries the date and time
●
SYSTEM INFORMATION
LV 5800 (MULTI MONITOR)
Command Parameter1
Description
SYS:UNIT1_INFO
-
Queries the unit 1 type
SYS:UNIT2_INFO
-
Queries the unit 2 type
SYS:UNIT3_INFO
-
Queries the unit 3 type
SYS:UNIT4_INFO
-
Queries the unit 4 type
SYS:UNIT5_INFO
-
Queries the unit 5 type
SYS:UNIT6_INFO
-
Queries the unit 6 type
●
LCD OFF
LV 5800 (MULTI MONITOR)
Command Parameter1
Description
SYS:LCD_OFF
-
Shuts off the LED.
●
INITIALIZE
LV 5800 (MULTI MONITOR)
Command Parameter1
Description
SYS:INIT
-
Initializes the LV 5800.
●
Miscellaneous
LV 5800 (MULTI MONITOR)
Command Parameter1
Description
REMOTE:HELP
-
Displays the list of the commands.
ON
Replies for the command.
REMOTE:REPLY (*1)
OFF
Does not reply for the command.(Default setting)
*1 Return value when REMOTE:REPLY is ON
If the LV 5800 is in the factory default condition (REMOTE:REPLY = OFF), the LV 5800 does not return a
value even when a command has an error during TELNET remote control. It only returns a value for queries
using a “?” parameter. This is done to maintain compatibility with the LV 5700.
By setting the REMOTE:REPLY command parameter to ON, the LV 5800 will return a value as follows:
OK:
If the command is processed properly.
ERR1:
If the number of parameters is incorrect.
ERR2:
If a parameter value is out of range.
ERR3:
If the function is not enabled in the current condition.
If the command itself is wrong, the LV 5800 will return the following character string.
-rbash:the incorrect command:command not found