The standard Remote Handset may be removed from the machine, and operated
effectively away from the issue site. The maximum recommended cable length is 30 Me-
tres.(100 Feet).
It is not recommended to plug/unplug the handset while the machine is still pow-
ered up. If this should occur, there is a possibility that the display will produce non read-
able characters if transmission is broken mid stream of a display update.
The rear panel of the machine is fitted with a 4 Pin ‘XLR’ connector which will allow
the connection of two 0 - 10 volt lines.
One line is of a switching characteristic for the activation of fog, simulating the
‘Smoke On’ switch, while the second line is for analog control of the ‘Flow Rate’.
Both lines can be used simultaneously for complete control, or either can be used
individually.
In the case of the ‘Flow Rate’ line being used alone, the ‘Smoke On’ switch will be
required to be set in the ‘On’ position, and a definite 0 volt condition available from the
controller to switch the fog output off.
No special selection of rear panel control switches is required for this mode of
operation.
The Pin Assignment for the connector port labeled
0-10 v Control
are as follows:
Pin 1 Common
Pin 2 Smoke On 0- 10V
Pin 3 Flow 0- 10 V
Pin 4 (Not used)
Analog 0-10V Control
7
Remote and External Control Features
Analog 0-10V Control
0-10V Control Pin Assignment