lemaitrefx.com
12
A-
Air pressure Gauge
: This is used as a visual aid to help in setting the air pressure used in
the steam simulation/ air purge effect.
B-
Air Pressure Control
: This is used to control the velocity of the steam/ air purge effect,
with the setting being displayed on the Air Pressure Gauge in p.s.i (pounds per square inch).
C-
Air Input
: This quick coupler connector is used as the input for the compressed air, and is
an industrial interchange 1/4” body.
D-
Continuous Air Over Ride
: This switch is used if continuous air output is desired. If show
control air is used, this switch must be in the off position.
E-
G300 Mode Control (Key Switch)
: The G300 is a dual operational machine which
operates in Haze (H) mode or Fog (G) mode. For the purpose of steam simulation, the fog (G)
mode is used ONLY. Fog (G) mode is activated when the key is in the horizontal position.
F-
Show Control Smoke On (Terminals)
: These show control terminals control the ‘fog’ ON
or OFF. These are dry contact controls, where the contacts are open or closed.
G-
Interval Control
: Controls the interval between fog bursts. If show control is used the
interval setting must be 0.
H-
Duration Control
: Controls the duration of fog bursts. If show control is used the duration
setting must be 0.
I-
Smoke Flow Control
: Controls the density of the steam effect and fog volume
J-
Show Control Air On (Terminals)
: These show control terminals control the air ON or OFF.
If Show Control is used the continuous Air Over Ride switch must be in the OFF position.
These are dry contact controls, where the contacts are open or closed.
G300 Steamer/ Air Purge Control List