1. Remove the six screws from the case. Four are under the lip at mid level and two are on
top. Remove the bolt from the front of the fluid jug. Slide the upper cover forward and
remove it from the machine. Lift the jug up and out of the way.
2. Remove the two screws from the front edge of the
block cover. Slide the cover backward to release the
two back tangs from the lower cover and lift the
cover off.
3. Unfasten the tube by releasing the 7/16” brass nut
at the pump. This line may be under significant
pressure if the tube was plugged.
4. Be careful not to damage any exposed wiring. Re-
move the upper steel plate by loosening the five
nuts with a 1/2” socket. Gently lift the plate back
out of the way leaving the high temperature switch
undisturbed.
5. Lift the aluminum plate up cautiously to avoid
damage to the Thermal sensor.
6. Remove the copper tube and two thin aluminum wear plates.
Battle Fogger Tube Change Procedure
Caution !
The block contains extremely hot surfaces and liquids. These will
cause severe burns on contact. Please unplug power to eliminate
electrocution hazard and allow the unit to cool before attempting to
service the block.