![Le Maitre Battle Fogger Operation Manual Download Page 6](http://html1.mh-extra.com/html/le-maitre/battle-fogger/battle-fogger_operation-manual_1864417006.webp)
1) The Battle Fogger must only be connected to a grounded mains supply capable of
sustaining at least 15 Amps. The supply should be ‘clean’ and free of interference.
2)
Open a container of Le Maitre fog fluid , remove cap and break foil seal (if provided).
Remove Cap from Battle Fogger fluid resevoir. Fill with fluid, being careful not to overfill
resevoir. Replace both caps securely.
3) Connect the remote handset supplied with the machine, to the connector which is located
on the rear panel.
4)
Activate the
Mains On
switch located on the rear panel. The Mains On switch will
illuminate to indicate the presence of power, the
handset
indicator on the remote hand-
set will also illuminate (or slow flash on startup). If the handset indicator of the remote
handset does not illuminate, ensure the connector is properly inserted.
5) The
handset
indicator will flash slowly as the machine heats up.The indicator will
begin flashing quickly when the fog machine is ready to operate. Fog is available at this
point, but full fog output will not be available. After approximately 9 minutes the indicator
will be solid when the fog machine has fully heated and is ready for use at full fog output if
required.
6) It may now be necessary to
prime
fluid into the system to expel any air that might be
present. The
Variflow
control on the
remote handset should be set to Full
position, set the
Duration
and
Interval
to zero and prime the fog machine
pump by activating the
Fog
switch on
for 1 second and off for 2 second
repeatedly until the machine is primed.
This only needs to be done if the unit
was left to run dry.
Operating Procedure