 3.2.3  STOPPING VOICE WARNING

To stop the issuance of a warning voice, in case it is a recorded message, push the button

of the message that hat you want to stop. To stop the live voice warning release the "Talk" button
on the microphone.

You can also stop issuing the condition by deactivating the emergency condition (see 3.2.4)

 3.2.4  DEACTIVATING EMERGENCY CONDITIONS

If   you   want   to   deactivate   the   emergency   condition,   press   “RESET”   for   2   seconds,   the

emergency condition will be deactivated. All the emergency warnings will be stopped.

 3.2.5  EVENT LAUNCHING

You can launch events that have been configured in the NEO system. In order to do this,

extension panels for event launching should be previously installed.

How to use programmed events:
To launch an event, push the EVENT button. The keyboards’ leds flash for a few seconds to

indicate that you have to select the appropriate button. Then the pushed button’s led flashes in
green, pointing out that the order has been processed. If it can’t be processed, the REMOTE led
will flash, indicating that it’s not possible to execute it.

For   you   to   be   able   to  stop   the  launched   events,   it’s  recommended   to   create   an   output

condition trigger and associate it to an unassigned button. 
 

 3.3  FAULT

 3.3.1  MUTING FAULT CONDITION

If   you   want   to   silence   the   audible   fault   indicator,   press   the   "ACK"   button.   The   audible

indicator will also be automatically muted when you press the "TALK" button on the emergency
microphone.

 3.3.2  RESETING FAULT CONDITION

To reset the fault condition press the "RESET" key for 2 seconds, the equipment will restart

the fault condition. If the fault condition persists, it will be indicated again.

 3.4  TESTING

To do a test of the equipment indicators, hold the "TEST" key. All indicators will light up

simultaneously and the audible indicator will sound. To stop the test, release the "TEST" key.

10

www.lda-audiotech.com/

 

 en

Summary of Contents for LDAVAP1

Page 1: ...Model VAP 1 User s Manual...

Page 2: ......

Page 3: ...t if it is not going to be used for several days Never pour liquid into the grilles it could cause fire or electric shock 10 Do never open the equipment For safety reasons the equipment should only be...

Page 4: ......

Page 5: ...ING 9 3 2 4 DEACTIVATING EMERGENCY CONDITIONS 9 3 2 5 EVENT LAUNCHING 9 3 3 FAULT 9 3 3 1 MUTING FAULT CONDITION 10 3 3 2 RESETING FAULT CONDITION 10 3 4 TESTING 10 4 CONNECTION AND SETTING UP 10 4 1...

Page 6: ......

Page 7: ...notices and the issuing of alert and evacuation messages through up to 56 selection memories of PA zones in a NEO system FUNCTIONS 1 Up to 56 zone memories with 8 addressing zones per memory 448 zones...

Page 8: ...hen the equipment is remotely controlled from the system controller or from another VAP 1 with higher priority This indicator is deactivated automatically when it starts to operate from the VAP 1 Ambe...

Page 9: ...corded messages of the system and the emergency microphone h EVAC EVACUATION Active on when the message that is being issued is intended for the evacuation of the voice alarm zone or zones selected Re...

Page 10: ...e equipment It allows to confirm that the indication of an emergency or fault condition has been noticed By pressing it the audible emergency or fault warning will be muted 2 2 4 EVAC MSG The EVAC MSG...

Page 11: ...terminator selector EOL is located in the middle of the rear part of the equipment It allows the activation deactivation of the bus terminator This control must be active when the equipment occupies...

Page 12: ...etermined by the selected identifier So we have ID 0 Memories 1 8 ID 1 Memories 9 16 ID 2 Memories 17 24 ID 3 Memories 25 32 ID 4 Memories 33 40 ID 5 Memories 41 48 ID 6 Memories 49 56 ID 7 Memories 5...

Page 13: ...bus is 1000m 3280ft Mark Description Type Signals Activation BUS ACSI Line level balanced audio Control bus and supply I O Protocol N A Table 1 ACSI Bus Connection NOTE This connection is not compatib...

Page 14: ...de with a miniUSB A male cable provided with the equipment 2 3 3 PORTS FOR EXPANSION KEYBOARDS The equipment has a port on the right side of the unit for connecting additional keyboards Mark Descripti...

Page 15: ...ushing the ACK key 3 2 2 ISSUING VOICE WARNING Once the emergency condition is activated you will be able to select the following options to make a voice warning Issuing a recorded warning message EVA...

Page 16: ...that you have to select the appropriate button Then the pushed button s led flashes in green pointing out that the order has been processed If it can t be processed the REMOTE led will flash indicati...

Page 17: ...ADDRESSING AND PRIORITY CONFIGURATION Each device has a switch priority in the bus Depending on the configured priority it will be allowed to occupy the channel while it is occupied by another device...

Page 18: ...rm RST to cancel the address change The computer will restart with the new bus address If when starting the VAP 1 REMOTE CTRL and EMG indicators light up simultaneously there is an address conflict wi...

Page 19: ...n the maximum or minimum volume is reached the EVAC or ALERT indicators will remain on Press the ACK button to confirm RST to cancel the change 4 5 EXPANSION KEYBOARDS CONNECTION The VAP 1 can equip u...

Page 20: ...Illustration 11 Expansion Keyboard Connection Step 1 Adaptor Illustration 12 Expansion Keyboard Connection Step 2 Illustration 13 Expansion Keyboard Connection Step 4 Block Illustration 14 Expansion...

Page 21: ...PDATE If an equipment Firmware update is required make sure that the update image provided matches your model If the equipment has expansion keyboards connected it is not necessary to disconnect them...

Page 22: ...the equipment with 4 M4 screws To adjust the width of the equipment you can use expansion keyboards or rack complements The following are the different combinations of installation where the keyboard...

Page 23: ...e equipment will indicate a link failure with the system when it detects that the transmission path is shorted or disconnected Check that the VAP 1 that does not link is the only bus that can not conn...

Page 24: ...ACSI bus of the equipment so that the rest of the system keeps working normally 7 3 NO INDICATOR LIGHTS UP If this is the case there is probably a problem with the power supply of the equipment If the...

Page 25: ...ss according 4 2 In case that the expansion keyboard does not work yet disconnect it from the VAP 1 and contact the support repair service 7 7 THE EXPANSION KEYBOARD DOES NOT LIGHT UP If when pressing...

Page 26: ...Operations Wipe with a damp cloth Clean the air inputs and outputs with a vacuum cleaner Check the connections of the equipment 20 www lda audiotech com en...

Page 27: ...Warning Indicators test Functions Prior notice tone volume control DSA Dynamic sound adjuster Directionality until 448 system zones Microphone cable length 500mm 13 75 Dimensions without microphone A...

Page 28: ...Ver 2...

Reviews: