Wyvern Timer 2000R Operating Instructions
19
Lockout Time
A safety feature built into the Wyvern 2000R Timer is the ability to prevent the timer
from exceeding a maximum time despite a customer inserting more coins or a card. This
lockout time is particularly useful in setting a limit to the exposure of UV radiation in tanning bed
applications.
Lockout will activate once a defined maximum time has been exceeded. During this time,
the display will flash an ‘L’ character to indicate lockout is active and additional coins are
rejected. If program codes 16 and 17 are set to zero lockout is not operative.
Important: Do not set lockout time to a value less than the session time (options 08 and 09).
Lockout can be initiated after the insertion of the first valid coin by using program code 3008,
during cool down with program code 3002 (page 26), or at the end of pre-time with special
option code 00.
Program
Codes
Description Maximum
Value
Value Used
16
Lockout time in hours or
minutes (see program code 22)
-
17
Lockout time in minutes or
seconds (see program code 22)
59
Special
Code
Description Maximum
Value
Value Used
00
Normal operation = OFF
Lockout at pre-time end = ON
-
Lockout Time Programming Codes
Buzzer Time
To warn that a timed operation is coming close to ending, a buzzer may be sounded.
Buzzer ON time is the time the buzzer is sounded before the timer switches OFF.
Buzzer duration is the time for which the buzzer is sounded.
To select the buzzer duration time in minutes select program code 3001 (see page 26)
Program
Codes
Description Maximum
Value
Value Used
18
Buzzer ON time in hours or
minutes (see program code 22)
MAX 59
19
Buzzer ON time in minutes or
seconds (see program code 22)
MAX 59
20
Buzzer duration time in seconds
MAX 59
Buzzer Time Programming Codes